background image

7

WARNING FIRE HAZARD

1(9(5H[KDXVWDLURUWHUPLQDWHGXFWZRUNLQWRVSDFHVEHWZHHQZDOOVFUDZOVSDFHVFHLOLQJDWWLFVRUJDUDJHV

 

$OOH[KDXVWPXVWEHGXFWHGWRWKHRXWVLGH

8VHVLQJOHZDOOULJLGPHWDOGXFWZRUNRQO\

)DVWHQDOOFRQQHFWLRQVZLWKVKHHWPHWDOVFUHZVDQGWDSHDOOMRLQWVZLWKFHUWL¿HG6LOYHU7DSHRU'XFW7DSH

Some Ducting Options

Installation – 

Ducting Options

side wall cap
w/ gravity damper

side wall cap
w/ gravity damper

Soffit or crawl space

Roof Pitch w/ 
Flashing & Cap

8” round or 
3-1/4”x10” rect. 
horizontal ducting

8” round 
vertical ducting

8” round 
vertical ducting

Summary of Contents for UIX3019S

Page 1: ...ide www windcrestcnp com Model number Serial Number Date of Purchase Sales Dealer Copyright 2014 CNP Industries Inc UIX3019S UIX3619S Insert with 600 CFM Blower READ AND SAVE THESE INSTRUCTIONS CFM Select GMXVWDEOH LUÀRZ 7HFKQRORJ ...

Page 2: ...www windcrestcnp com ...

Page 3: ... Electrical 9 DELQHW 3UHSDUDWLRQ QVWDOODWLRQ 10 9HUWLFDO XFWLQJ 3UHSDUDWLRQ 11 RUL RQWDO XFWLQJ 3UHSDUDWLRQ 12 14 FEATURES CONTROLS 7RXFK RQWUROV 15 16 RF Remote Control 17 MAINTENANCE OHDQLQJ DQG QVWDOOLQJ LOWHUV 18 LJKWV 19 TROUBLESHOOTING 20 FAN CURVE WIRING DIAGRAMS 21 22 LIST OF PARTS AND ACCESSORIES 23 WARRANTY 24 Table of Contents ...

Page 4: ...G XWHQVLOV DSSURSULDWH IRU WKH W SH RI DQG DPRXQW RI IRRG EHLQJ SUHSDUHG WARNING 72 5 8 7 5 6 2 1 85 72 3 56216 1 7 9 17 2 5 1 723 5 2 6 59 7 2 2 1 D 6027 5 0 6 ZLWK D FORVH WWLQJ OLG FRRNLH VKHHW RU PHWDO WUD WKHQ WXUQ RII WKH EXUQHU 5 8 72 35 9 17 8516 I WKH ÀDPHV GR QRW JR RXW LPPHGLDWHO 9 8 7 1 7 5 3 570 17 E 1 9 5 3 83 0 1 3 1 RX PD EH EXUQHG F 2 127 86 7 5 LQFOXGLQJ ZHW GLVKFORWKV RU WRZHOV ...

Page 5: ... QHXWUDO RU JURXQG FLUFXLW 1DWLRQDO LUH 3URWHFWLRQ VVRFLDWLRQ DWWHU PDUFK 3DUN 4XLQF 0DVVDFKXVHWWV 6 QWHUQDWLRQDO DVW 3OHDVDQW 9DOOH 5RDG OHYHODQG 2KLR 7KLV DSSOLDQFH UHTXLUHV D 9 HOHFWULFDO VXSSO DQG FRQQHFWHG WR DQ LQGLYLGXDO SURSHUO JURXQGHG EUDQFK FLUFXLW SURWHFWHG E D RU DPSHUH FLUFXLW EUHDNHU RU WLPH GHOD IXVH LULQJ PXVW EH ZLUH ZLWK JURXQG 3OHDVH DOVR UHIHU WR OHFWULFDO LDJUDP RQ SURGXFW UI...

Page 6: ...UHFWDQJXODU DGDSWRU Z GDPSHU RUL RQWDO GXFWLQJ EORZHU PRXQW EUDFNHWV 7RS UHFWDQJXODU FRYHU SODWH 5 UHPRWH FRQWURO Z EDWWHU KROGHU DUGZDUH SDFNDJH HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED XFWLQJ FRQGXLW DQG DOO LQVWDOODWLRQ WRROV Cable connector if required by local codes Light Bulb Removal Suction Cup 1 M4 x 6mm 8 Wire Caps 3 8 x 1 2 12 3 16 x 3 8 10 Remote Holder 1 RF Remote Control 1 ...

Page 7: ... Ft Ft 6 Round straight 1 Ft x Ft Subtotal column 1 Duct pieces T otal Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 10 Round 900 elbow 15 Ft x Ft 7 10 7 10 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 Round roof cap 30 Ft x Ft 7 10 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork 6 roundto 3 1 4 x 10 rect transi...

Page 8: ...U WKDQ 36 W LV LPSRUWDQW WR LQVWDOO WKH KRRG DW WKH SURSHU PRXQWLQJ KHLJKW RRGV PRXQWHG WRR ORZ FRXOG UHVXOW LQ KHDW GDPDJH DQG UH KD DUG ZKLOH KRRGV PRXQWHG WRR KLJK ZLOO EH KDUG WR UHDFK DQG ZLOO ORVH LWV SHUIRUPDQFH DQG HI FLHQF I DYDLODEOH DOVR UHIHU UDQJH PDQXIDFWXUHU V KHLJKW FOHDUDQFH UHTXLUHPHQWV DQG UHFRPPHQGHG KRRG PRXQWLQJ KHLJKW DERYH UDQJH Vertical Ducting 8 round minimum Horizontal D...

Page 9: ...O ULJLG PHWDO GXFWZRUN RQO DVWHQ DOO FRQQHFWLRQV ZLWK VKHHW PHWDO VFUHZV DQG WDSH DOO MRLQWV ZLWK FHUWL HG 6LOYHU 7DSH RU XFW 7DSH Some Ducting Options Installation Ducting Options side wall cap w gravity damper side wall cap w gravity damper Soffit or crawl space Roof Pitch w Flashing Cap 8 round or 3 1 4 x10 rect horizontal ducting 8 round vertical ducting 8 round vertical ducting ...

Page 10: ...Installation 6SHFL FDWLRQV Top View 3 4 View Back View 28 3 8 34 3 8 12 12 3 22 3 8 28 3 8 19 1 4 28 14 1 4 34 17 1 4 5 5 8 1 1 2 C L Ø 7 3 4 28 9 1 4 34 12 1 4 2 elec k o 10 3 4 28 9 1 4 34 12 1 4 9 7 8 C L 3 1 4 5 1 2 7 3 4 ...

Page 11: ... or prevailing local codes and ordinances Electrical Supply 7KLV DSSOLDQFH UHTXLUHV D 9 HOHFWULFDO VXSSO DQG FRQQHFWHG WR DQ LQGLYLGXDO SURSHUO JURXQGHG EUDQFK FLUFXLW SURWHFWHG E D RU DPSHUH FLUFXLW EUHDNHU RU WLPH GHOD IXVH LULQJ PXVW EH ZLUH Z JURXQG 3OHDVH DOVR UHIHU OHFWULFDO LDJUDP ODEHOHG RQ SURGXFW Cable Lock FDEOH ORFNLQJ FRQQHFWRU QRW VXSSOLHG PLJKW DOVR EH UHTXLUHG E ORFDO FRGHV KHFN ZL...

Page 12: ...GHV WARNING Make sure the surface you are securing the liner to is capable of holding the weight of UIX3019S UIX3619S Failure to do so may cause personal injury or damage to cooking surface or counter LQDOL H LQVWDOODWLRQ RI HOHFWULFDO DQG GXFW ZRUN 6HDO GXFW ZRUN ZLWK FHUWL HG DOXPLQXP GXFW WDSH 3RZHU RQ OLQHU FKHFN IRU OHDNV DURXQG GXFW WDSH DQG YHULI SURSHU RSHUDWLRQ NOTE I DFFHVV WR WRS RI OLQ...

Page 13: ...QHOV E UHPRYLQJ VFUHZV IURP EHKLQG HDFK SDQHO Installation Vertical Ducting Preparation 1 2 1 1 2 Locking Tabs Bottom Panel Screws 2 1 4 5HPRYH ERWWRP SDQHO E 1 5HPRYLQJ VFUHZV IURP OHIW DQG ULJKW VLGHV RI ERWWRP SDQHO 2 3XOOLQJ ERWWRP SDQHO WRZDUG IURQW RI OLQHU WR UHOHDVH IURP ORFNLQJ WDEV 6 9HUWLFDO GXFWLQJ SUHSDUDWLRQ LV FRPSOHWH 5HIHU WR SDJH 10 VWHS 4 WR FRPSOHWH LQVWDOODWLRQ 5 6HFXUH URXQG ...

Page 14: ... VLGH VSDFHU SDQHOV E UHPRYLQJ VFUHZV IURP EHKLQG HDFK SDQHO 1 2 1 1 2 Locking Tabs Bottom Panel Screws 2 1 4 5HPRYH ERWWRP SDQHO E 1 5HPRYLQJ VFUHZV IURP OHIW DQG ULJKW VLGHV RI ERWWRP SDQHO 2 3XOOLQJ ERWWRP SDQHO WRZDUG IURQW RI OLQHU WR UHOHDVH IURP ORFNLQJ WDEV 6 5HPRYH EORZHU IURP OLQHU E UHPRYLQJ WKH VFUHZV IURP WKH WRS RI WKH OLQHU 6HW VFUHZV DVLGH IRU ODWHU XVDJH 5 LVFRQQHFW EORZHU PROH SO...

Page 15: ...127 0DNH VXUH WKH FRYHU SODWH WDEV DUH RQ WRS RI WKH FRYHU SODWH DV VKRZQ URP LQVLGH WKH OLQHU VHFXUH SODWH WR WRS RI OLQHU ZLWK VFUHZV A A B C C B 8 5HPRYH NQRFN RXWV DQG IRU UHFWDQJXODU GXFWLQJ 5HPRYH NQRFN RXWV DQG IRU URXQG GXFWLQJ Rect GXFWLQJ Round GXFWLQJ At this point install the one piece liner into the cabinet by following the steps on Page 10 Step 4 After the liner installation continue...

Page 16: ...DSV DURXQG WKH NQRFN RXW SODWH E XVLQJ FHUWL HG DOXPLQXP GXFW WDSH 3OXJ LQ EORZHU PROH SOXJ Horizontal ducting preparation is now complete Refer to Page 10 Step 5 to complete installation 10 Rectangular Ducting URP LQVLGH WKH OLQHU SXVK UHFWDQJXODU DGDSWRU WKURXJK WKH EDFN NQRFN RXW DQG VHFXUH WR LQWHULRU EDFN ZDOO RI OLQHU ZLWK 0 PP VFUHZV 10 Round Ducting URP LQVLGH WKH OLQHU SXVK URXQG DGDSWRU ...

Page 17: ... by pressing to decrease and to increase speed levels The display indicates levels selected CFM Select Enabled Speed Selections When CFM Select is enabled the number of blower speeds will be reduced as follows 390 CFM Maximum 3 speeds 290 CFM Maximum 2 speeds 3 Delay Off This feature is used for programmed shut down of blower 5 minutes after the function is activated Press once a dot flashes in th...

Page 18: ...the filter clean reminder timer after filters are cleaned and re installed With hood off press and hold for approximately 5 seconds until on display disappears The filter clean reminder function is now reset and a new 30 hours elapse cycle is initiated F Clean Filters display F flashes F hold 5 sec display from F to To Reset F A hold 3 sec display from A to To Disable hold 3 sec To Enable F F disp...

Page 19: ...DFN IRU HDV VWRUDJH 7KH UHPRWH PD EH SODFHG RQ DQ PDJQHWLF VXUIDFH VXFK DV D UHIULJHUDWRU RU WKH LQG UHVW UHPRWH KROGHU 7KH UHPRWH KROGHU FDQ EH LQVHUWHG LQWR D VWDQGDUG HOHFWULFDO RXWOHW IRU HDV VWRUDJH 1RWH 7KH UHPRWH KROGHU GRHV QRW FKDUJH WKH 5 UHPRWH 0D LPXP UHPRWH FRQWURO FRPPXQLFDWLRQ GLVWDQFH LV IHHW IURP WKH OLQHU SYNCHRONIZATION 7R FUHDWH D XQLTXH OLQN EHWZHHQ RXU OLQHU DQG UHPRWH FRQWUR...

Page 20: ...ated on the liner controls LOWHUV PD EH SODFHG LQ GLVKZDVKHU DW ORZ KHDW RU VRDNHG LQ KRW VRDS ZDWHU U OWHUV DQG UH LQVWDOO EHIRUH XVLQJ KRRG QVWDOOLQJ WKH DIÀH LOWHUV 3ODFH OWHU LQWR WRS JURRYH RI WKH OLQHU DV VKRZQ DQG SXOO WRZDUGV IURQW RI OLQHU XVLQJ KDQGOHV 3LYRW EDFN RI OWHU XSZDUGV VR LW LV DQJOHG LQ WKH OLQHU 3XVK OWHU LQWR FKDQQHO RQ EDFN RI OLQHU WR ORFN LQWR SODFH 5HSODFLQJ WKH DIÀH LOW...

Page 21: ...RYH E WXUQLQJ EXOE FRXQWHU FORFNZLVH Note XOE GRHV QRW XQVFUHZ LW WXUQV GHJUHHV VWRSV DQG IDOOV RXW I EXOEV DUH GLI FXOW WR WXUQ GXH WR SURORQJHG XVH UPO DWWDFK WKH JODVV VXFWLRQ FXS SURYLGHG WR WKH EXOE RU XVH D UXEEHU ODWH JORYH DQG WXUQ FRXQWHU FORFNZLVH 5HSODFHPHQW EXOEV DUH DYDLODEOH DW VSHFLDOW OLJKWLQJ VWRUHV 3XUFKDVH W SH 05 8 KDORJHQ RU LQG UHVW SDUW QXPEHUV SOHDVH WXUQ WR SDJH RI WKH PDQ...

Page 22: ...RQ RI WKH OLQHU DPDJHG EORZHU ZKHHO KDQJH WKH EORZHU 7KH XQLW LV ZKLVWOLQJ OWHU LV QRW LQ WKH FRUUHFW SRVLWLRQ GMXVW WKH OWHUV XQWLO WKH ZKLVWOLQJ VWRSV 7KH GXFW SLSH FRQQHFWLRQV DUH QRW VHDOHG RU FRQQHFWHG SURSHUO KHFN WKH GXFW SLSH FRQQHFWLRQV WR EH VXUH DOO FRQQHFWLRQV DUH VHDOHG SURSHUO 7KH EORZHU LV ZRUNLQJ EXW WKH OLJKWV DUH QRW 7KH OLJKW EXOE LV ORRVH 7LJKWHQ WKH EXOE DQG PDNH VXUH LW V VHF...

Page 23: ...O VHW WKH PD LPXP EORZHU VSHHG WR RQH RI WZR PRVW FRPPRQO VSHFL HG 0 OHYHOV RU 0 7KH XVDJH RI 0 6HOHFW PD QRW EH QHFHVVDU IRU RXU LQVWDOODWLRQ 3OHDVH FKHFN RXU ORFDO FRGHV IRU 0 UHVWULFWLRQV By default the maximum blower CFM is set to 600 7R YHULI LI RXU LQVWDOOHU HQDEOHG 0 6HOHFW LWK KRRG RII SUHVV DQG KROG WKH EORZHU RQ RII EXWWRQ IRU WKUHH VHFRQGV I WKH QXPEHU GLVSOD V GHIXDOW PD 0 LI WKH QXPEH...

Page 24: ...2 3 2 4 2 5 2 6 2 7 2 8 Pressure inAq Blower Fan Curve 600 CFM AC Input 120V 60Hz Outlet Diameter 8in 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 400 425 450 475 500 525 550 575 600 625 650 675 700 725 750 Flow rate CFM Model UIX3019S UIX3619S CFM Select ...

Page 25: ...s LJKW XOE 05 8 HDFK 6 8 6 8 6 DIÀH LOWHU DUJH HDFK 6 8 6 DIÀH LOWHU 6PDOO HDFK 6 RF Remote Control S12313 00 LJKW XOE 5HPRYDO 6XFWLRQ XS 6 7R RUGHU SDUWV YLVLW XV RQOLQH DW ZZZ ZLQGFUHVWFQS FRP RU FDOO XV DW List of Parts and Accessories ...

Page 26: ...ized agency or use of unauthorized parts 2 Service visits to teach you how to use the appliance 3 Correct installation related problems you are responsible for providing electrical wiring and other connection items 4 Reset circuit breakers or replace fuses 5 Damage caused by abuse accident alteration misuse and local code violations 6 Failure due to other than normal house use You may also write t...

Reviews: