71
6.
El
ectric
al Connection Diagr
ams
Fuse 6,3 A
2
1
12
GND
-XD
c
ap
ac
it
o
r
2
1
ig
n
it
ion
el
e
me
n
t
2
1
b
la
ck
b
ro
wn
b
lu
e
-XG
ha
ll
s
e
nsor
br
o
w
n
bl
u
e
bl
a
ck
-S
4
p
ro
ximi
ty
swi
tch
p
e
lle
t
h
o
p
pe
r
e
x
te
rn
a
l
he
a
t
d
e
m
a
n
d
24
2
3
Lon-
Lon+
GND
-X
L
1
12V
3
N'
6
L'
5
L
1
N
2
N
PE
PE
P
E
1
3
2
-XB
3
2
1
-XG
PE
-XS
-X
L4
Lo
n
-
Lo
n
+
G
ND
-XL3
12
V
N
G
N
D
1
2
V
L
230V
12V DC
-T2.1
transformer
230V / 12V DC
1
2
4
-B8.1
conveyor screw 100°C
safety temperature
limiter
M
PE
L2
N
P
E
L1
motor for conveyor
screw
-M2.1
1
2
d
o
or
sa
fe
ty
swi
tch
2
2
2
1
4
2
41
-X2
eme
rg
en
cy
he
a
ti
n
g
o
ff
sw
it
c
h
L
PE
N
supply
230V
-XN
L
PE
N
co
ntro
l
-XR
w
h
it
e
g
re
en
c
o
mb
u
st
io
n
c
h
am
b
e
r
s
e
n
s
o
r
-V
9
.1
fl
u
e
g
as
s
en
so
r
-V
14
.1
2
3
1
PE
4
L
PE
L
1
N
P
E
induced draught
motor fan
-M6.1
4
5
6
L
on
-
Lo
n
+
G
ND
-XL2
12
V
3
2
1
-XZF
6
1
2
lim
it
sw
itch
a
sh
re
mov
al
2
1
4
3
M
PE
L2
N
PE
L1
motor for ash
removal
-M12.1
PE
P
E
yellow
orange
red
brown
1
2
3
1
2
4
-B7.1
safety temperature
limiter boiler 100°C
1
N
2
N
3
L
4
L
-XA
b
o
iler
se
n
so
r
-V
4
.1
5
4
b
ro
wn
b
lue
b
lack
N
ä
he
run
g
ssch
a
lt
e
r
D
e
ckel
-P
9
.1
X1
X17
X22
X21
X16 X15
X14
X13
X18
X12
X11 X10
X2
X19
X20
X5
X6
X24
X7
X3
X4
X8
X9
2
2
1
1
4
3
2
1
2
1
3
2
1
6
5
4
3
2
1
2
1
2
1
3
2
1
3
2
1
L
on
-
L
on
+
G
N
D
+
1
2
V
G
N
D
Lo
n
+
L
on
-
+
12V
1
2
3
1
2
1
2
3
4
1
2
3
1
2
3
4
1
2
1
2
3
4
5
6
1
2
3
1
2
3
1
2
1
2
3
4
E
D
V
N
R
.:
01
19
9
0
L
N
PE
L
N
LL
N
P
E
R
L
L
L
L
N
PE
L
N
PE
N
PE
N
L
L
N
PE
L
L
'
L
'
L
N
PE
L
L
N
PE
LON
F
A
-Bi
o
W
IN
2
co
n
n
e
ct
io
n
p
o
w
e
r
su
p
p
ly
2
30
VAC
su
ct
ion
turb
in
e
p
ro
b
e
sw
it
chi
n
g
ash
re
m
o
va
l
op
e
n
ig
ni
ti
o
n
el
e
m
en
t
ash
re
m
o
va
l
clo
se
m
o
tor
h
ea
tin
g
su
rf
a
ce
cl
ea
n
ing
m
o
tor
a
sh
re
m
o
val
S
T
L
scr
e
w
S
T
L
b
o
ile
r
co
n
ve
yo
r
scr
e
w
suct
io
n
dr
a
ug
ht
-
ID-
fa
n
limit
sw
itch
fl
a
p
/
cap
G
N
D
1
2V
lim
it
sw
itch
zer
o
p
o
int
S
10
G
N
D
lim
it
sw
it
ch
p
o
sitio
n
S
1
1
G
N
D
e
xt
er
n
al
h
e
a
t
d
e
man
d
G
N
D
com
b
ustio
n
ch
a
mb
e
r
do
o
r
sw
it
ch
GND
lim
it
swi
tch
ash
remo
val
GND
ta
nk
e
m
p
ty
1
2
V
in
pu
t
I/
O
ha
ll.
si
g
n
a
l
ha
ll.
GND
ha
ll.
5
V
+
G
N
D
a
na
lo
g
0
-1
0
V
G
N
D
b
o
ile
r
se
n
so
r
G
N
D
co
m
b
u
st
io
n
ch
a
m
b
e
r
se
n
so
r
G
N
D
fl
u
e
g
a
s
te
m
p
.
sen
so
r
G
N
D
p
re
ssu
re
sw
it
ch
p
re
ssu
re
s
w
it
ch
-P
2
.1
*...optional/accessories
** remove resistor R2 to connect an extension control
6.2 Pellet boiler basic circuitry with manual pellet feed
094751/00
Connection to
wood gasification boiler
3-pin
GND / Lon+ / Lon–
Summary of Contents for DuoWIN
Page 15: ...15 2 For the Installer ...
Page 69: ...69 5 Technical Data ...