PERMANENTLY CONNECTED EQUIPMENT must have a circuit breaker or switch included in the installation. It
must be suitably located and easily reached. It must be marked as the disconnecting device for the equipment.
It must be rated for the environment, the voltage, and the amount of power required by the entire system.
Access to disconnect devices must not be obstructed.
The Gateway is supplied with integral 30’ long 22AWG power cables. It is recommended for the installer to terminate power
into an approved junction box near equipment installation location. Conductors must be of sufficient size to carry the amount
of current required for the entire system.
3.7
Environment
This equipment has been rated for outdoor use. Refer to Spotlight Datasheet for details. Enclosures exposed to sunlight may
also be heated above the rated temperature. Supplemental cooling may be required in these environments.
4
Maintenance and Cleaning
The Windrock Spotlight contains no user serviceable parts and requires no routine maintenance. Repair and support are
provided by Windrock Inc. only.
Firmware and software updates are available periodically. Both the Gateway and Controller automatically installs updates as
needed.
The use of cleaning chemicals is not recommended. Dust and dirt may be removed with a soft cloth.
5
Appendix.
5.1
Gateway Control Drawing
5.2
Gateway Mounting Options
PRESSURE WASH WARNING. Use of harsh cleaning chemicals, solvents, and degreasers may impare the
functionality of the system. When pressure washing, be cautious on length of time and intensity of spray on all
parts of the system, including sensors and cabling. If parts of a Spotlight system were removed in order to
perform cleaning and/or maintenance, contact Windrock Product Support at 865-330-1100 and ask for
Spotlight Installation Support to verify operation.
IMPORTANT: POWER REQUIREMENTS. If voltage and power requirements are not
met, system integrity will be compromised. Review power requirements and
warnings as laid forth in this document. For additional details, refer to the Spotlight
Datasheet.