MAINTENANCE
86324160 AXCESS 03/23/09
4-3
!
CAUTION
REMOVING BLOCKAGES
Never clean the hose with
a stick or pointed object.
If there is a blockage, check the pad area (under
side) first. To do this first remove the floor pad, see
“Changing the Floor Pad”. Also check the suction
duct . Push the release button and remove the
suction duct access cover. Check the swivel neck
of the Polisher. Ensure there is no blockage
between the suction duct and the inlet of the swivel
neck.
If the orange bag full indicator is showing after the
filter bag has been changed and the filters are in
good condition, there is likely a blockage in the
system. First, check for suction at the end of the
hose. If you can only feel a small amount of
suction, the blockage is in the hose. To unblock,
loosen the safety ring on the lid. Remove the hose
from the machine and reverse the airflow through
the hose by putting the hose handle in the
connecting tube of the filter cover. Stretch the hose
in the spot where the blockage is and open and
close the end of the hose. Also check the suction
opening, which the hose handle fits into.