40
Maintenance
1. Squeegee
Retainer Latch
2. Squeegee
Squeegee Blades - Disk / Orbital
The front squeegee blade allows solution to pass
through channels in the blade into the squeegee
assembly while maintaining vacuum to provide lift. The
front blade has four wear surfaces and can be rotated
for extended life. The front blade should not require
regular replacement under normal use.
The rear blade wipes the floor to a near dry condition. It
is important the rear blade be in good condition to
properly do its job. As with the front, each squeegee
blade assembly has four wear surfaces for extended
service.
Check both the front and rear squeegee blades for
damage and wear each day in the pre-run check.
Change the front blade if it is torn or has an uneven
edge. Change the rear blade if it is less than half the
original thickness.
To Remove Squeegee Assembly
1. With the squeegee in the up position, turn key
switch “OFF”.
2. Disconnect vacuum hose from squeegee and
squeeze the squeegee retaining latch.
3. Pull squeegee assembly from the squeegee arm.
4. Inspect or repair as necessary and reinstall.
To Replace or Rotate Squeegee Blades
1. With the squeegee in the up position, turn key
switch “OFF”.
FOR SAFETY: Before leaving or servicing machine;
stop on level surface, turn off machine and remove
key.
2. Remove the squeegee assembly from the
machine.
3. Unscrew each of the four (4) knobs until they are
nearly removed from the squeegee assembly.
Grasp the squeegee assembly and push on the
knobs to remove the blade retainer.
Remove the knobs and pull the blade retainer out.
Rotate the squeegee blade to new edge position or
replace as required. Each blade has four (4) new
edge positions.
4. Pull the blades off the retainer.
To reinstall the blades, hook the blades over the
pins on the retainer plate.
5. Lower the retainer with blades back in position in
the squeegee assembly and install the knobs.
86398220 Operators Manual - Chariot-2 iScrub 20
1
2
DISK