51
Maintenance
1.
SOLUTION STRAINER
Located in bottom of tank. The strainer protects the ball valve and solenoid valve from debris. If the ball valve
and solenoid valve are not working, then check the strainer for debris.
Drain the solution tank.
Reach down to the strainer and remove debris. If the strainer can not be cleaned in place remove strainer.
To remove the strainer, rotate the strainer counterclockwise.
Clean out the debris from wire mesh and re-assemble.
2.
SHUT-OFF FLOW VALVE
Located below the solution tank on the right side. If no flow, check lever position.
Horizontal is no flow.
Up is maximum flow.
If clogged, in the maximum position, unscrew fittings, inspect and clean if needed.
3.
SOLENOID VALVE
The solenoid valve shuts off solution flow to scrub deck whenever scrubbing stops.
The solenoid valve is mounted on the front of the scrub deck, on left side.
Shut off manual water supply valve on right side of machine.
Disconnect the two (2) spade connections.
The solenoid valve snaps into place, rock the solenoid valve back and forth while lifting to free it.
Remove valve from supply hose.
86398220 Operators Manual - Chariot-2 iScrub 20