background image

SABER (SC)   86038350   01/29/07 

2-1 

IMPORTANT SAFETY INSTRUCTIONS 

When using an battery powered appliance, basic precaution 

must always be followed, including the following: 

READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. 

 

 

 

 

 

To reduce the risk of fire, electric shock, or injury: 

 

Use only

 indoors. Do not use outdoors or expose to rain. 

Use only

 as described in this manual. Use only manufacturer’s recommended components and 

attachments. 

If the machine is 

not working properly

, has been dropped, damaged, left outdoors, or dropped into 

water, return it to an authorized service center. 

Do not

 operate the machine with any openings blocked. Keep openings free of debris that may reduce 

airflow. 

This machine 

is not

 suitable for picking up hazardous dust. 

Machine can cause a fire

 when operating near flammable vapors or materials. Do not operate this 

machine near flammable fluids, dust or vapors. 

This machine is suitable for commercial use, for example in hotels, schools, hospitals, 
factories, shops and offices for more than normal housekeeping purposes. 

Maintenance and repairs 

must be done

 by qualified personnel. 

If foam or liquid comes out of machine, 

switch off immediately

Disconnect

 battery before cleaning or servicing. 

Before the machine is discarded, the batteries 

must be removed

 and properly disposed of. 

Make sure all warning and caution labels 

are legible and properly attached

 to the machine.

 

During operation

, attention shall be paid to other persons, especially children. 

Before use

 all covers and doors shall be put in the positions specified in the instructions. 

When leaving unattended

, secure against unintentional movement. 

The machine shall only

 be operated by instructed and authorized persons. 

When leaving unattended

, switch off or lock the main power switch to prevent unauthorized use. 

Only chemicals recommended

 by the manufacturer shall be used. 

This appliance has been designed

 for use with the brushes specified by the manufacturer.  The fitting 

of other brushes may affect its safety. 

Do not

 use on surfaces having a gradient exceeding 2%. 

 

 

SAVE THESE INSTRUCTIONS 

WARNING: 

Summary of Contents for Saber Compact 10052190

Page 1: ...diese Anleitungen bevor Sie die Maschine in Gebrauch nehmen MODELS SC20 SCC20 10052190 10052230 SC20T SCC20T 10052200 10052240 SCX20T SCXC20T 10052370 10052420 Operating Instructions Bedienungsanleit...

Page 2: ...__________ OVERVIEW The Saber Compact is a battery powered hard floor scrubber intended for commercial use The appliance applies a cleaning solution onto a hard floor scrubs the floor with a brush or...

Page 3: ...andle Group Non Traction 5 1 Control Tower Group Traction 5 3 Decal Group 5 5 Electrical Panel Group Non Traction 5 7 Electrical Panel Group Traction 5 9 Hour Meter 5 11 Recovery Tank Group 5 13 Scrub...

Page 4: ...rushes Squeegee Service Schedule Machine Troubleshooting The PARTS LIST section contains assembled parts illustrations and corresponding parts list The parts lists include a number of columns of infor...

Page 5: ...hotels schools hospitals factories shops and offices for more than normal housekeeping purposes Maintenance and repairs must be done by qualified personnel If foam or liquid comes out of machine swit...

Page 6: ...is information carefully Know when these conditions can exist Locate all safety devices on the machine Please take the necessary steps to train the machine operating personnel FOR SAFETY DO NOT OPERAT...

Page 7: ...achine If at any time the labels become illegible promptly replace them SAFETY DECAL 86252530 PRV NO 81494 BATTERY CAUTION 86252520 PRV NO 80885 CAUTION Explosive Gas is Given Off By Batteries During...

Page 8: ...Gravity feed fully variable with automatic shut off in neutral Solution tank capacity 13 gal 50 l Recovery tank capacity 16 gal 60 l Scrub brush diameter 20 in 51 cm Scrub brush pressure non traction...

Page 9: ...ted sound pressure level emitted by the appliance was measured to be 72 5 dBA This is a space averaged broad band measurement determined according to IEC 704 I This appliance contains no possible sour...

Page 10: ...or drives the brush The brush drive hub allows the scrub brush to follow irregularities and changes in the floor without loosing contact with floor The self adjusting scrub deck skirt controls the cle...

Page 11: ...ol Handle 3 Recovery Tank 4 Recovery Tank Drain Hose 5 Scrub Head 6 Scrub Brush Access Cover 7 Solution Tank 8 Solution Tank Cover 9 Solution Tank Drain Hose 10 Solution Strainer 11 Solution Tank Supp...

Page 12: ...SABER SC 86038350 01 29 07 3 5 1 Brush Switch 2 Brush Lift Lever 3 Vacuum Switch 4 Squeegee Lift Lever 5 Solution Control Lever 6 Battery Charge Level Indicator 7 Hour Meter Optional 8 Circuit Breake...

Page 13: ...INDICATOR Indicates the charge level of the batteries The meter display is divided into 10 vertical bars Bars illuminated on the far right indicate full charge Bars flashing near the left side indicat...

Page 14: ...rush Lift Lever 4 Vacuum Switch 5 Squeegee Lift Lever 6 Key Switch 7 Propel Buttons Normally Forward 8 Reverse Propel Button 9 Speed Control Knob 10 Battery Charge Level Indicator 11 Emergency Shut Of...

Page 15: ...ed position To raise the brush lift the lever from its lowered position and lock into highest notch 4 VACUUM SWITCH Controls the vacuum motor To start vacuum motor press the top of the switch To stop...

Page 16: ...ull charge if the batteries are disconnected then reconnected After a few minutes of operation the meter will give the correct charge level 11 EMERGENCY SHUT OFF SWITCH OPTIONAL Shuts off machine To s...

Page 17: ...Remove solution tank cover 3 Fill the solution tank with clean water leaving enough room for the required amount of cleaning solution The solution tank capacity is 13 gallons 50 liters The water must...

Page 18: ...activated flow will automatically resume TO STOP SCRUBBING 1 Release the directional control button s if your machine is traction model 2 Turn the scrub brush off 3 Raise the scrub brush 4 Raise the s...

Page 19: ...eplace the drain plug and secure the drain hose in the bracket RECOVERY TANK 1 Unhook the large drain hose from the retainer Unscrew the T handle on the plug enough to loosen it then lower the hose in...

Page 20: ...y cell before and after charging the batteries Never add acid to the batteries use distilled water Do not allow water level to fall below the battery plates Portions of plates exposed to air will be d...

Page 21: ...specific reading 0 004 4 points for each 10 F 6 C below 80 F 27 C TO CHARGE THE BATTERIES When servicing machine avoid contact with battery acid Batteries emit hydrogen gas Explosion or fire can resul...

Page 22: ...atteries during charging cycle 2 Connect charger s AC power cord to AC mains The charger s YELLOW AC LED will light Note When charger is energized all machine function will shut down 3 After several s...

Page 23: ...Nylon bristles are used in a variety of applications on coated or uncoated surfaces White Pads Polishing are used for dry polishing to achieve a high gloss appearance or surface washing on highly pol...

Page 24: ...Nylon bristles are used in a variety of applications on coated or uncoated surfaces White Pads Polishing are used for dry polishing to achieve a high gloss appearance or surface washing on highly pol...

Page 25: ...equired 4 Install blade with ribbed surface facing out 5 Install squeegee retainer strap 6 Install all screws starting from center and working to ends DELUXE SQUEEGEE BLADES The front squeegee blade a...

Page 26: ...rier bracket clockwise To decrease the deflection turn the knob counterclockwise NOTE The deflection should be consistent along the length of the squeegee If the deflection varies from end to end the...

Page 27: ...tor to dry Store with dome off tank to allow the tank to dry Check scrub deck splash skirt Check batteries for corrosion cracks and evidence of overheating Check all bearings for noise Check all gaske...

Page 28: ...n or runs slowly Recovery tank full Drain recovery tank Circuit breaker tripped Reset circuit breaker Loose connection Check motor wires and connections Faulty vacuum contractor Replace contactor Worn...

Page 29: ...traction model only Clean or replace No power to machine Battery disconnected Check all battery cable connections Emergency shut off activated traction model only Reset Battery connections corroded Cl...

Reviews: