Page 11
3.3.
Installation of the inside unit
Due to the diversity of wine cabinets and the type of locations, each installer must adapt to the
constraints of its installation.
-
Use insulated ducting
Ø125mm
-
Make sure to choose the perfect place to
have a length of the shortest ducting
possible (14m max / reduce 1 m by
number of elbow)
-
Radius elbow ≥ 175 mm
-
Do not reduce the duct section
-
The suction and blowing should in no way be
even partially obstructed
-
The blowing and suction should be
separated to avoid a resumption of the air
supply, even partially (for checking, the
suction temperature should be the same
as the room temperature when the unit
produces cold)
-
Provide openings on the bottom for
suction and blowing
-
Provide space for refrigeration and
electrical connections and the passage of
the condensate drain
Two decoration grids are supplied with the unit. These grids are adapted to the air flow
.
SUCTION
BLOWING