Item
Function
Effect
006
CANCEL VENTILATION button
WARNING
Explosion hazard. Cancel the exhaust ventilation only in
an urgent situation. Gas could stay on the engine side, if
the exhaust ventilation is not sufficient.
Stops the exhaust ventilation
007
Preconditions
Shows the different precondition status
Shows: CA Status unknown, CA Position not OK, Aux Blowers
not running, SO Service Pump not running, Ready
008
Exhaust Ventilation Info
Shows the exhaust ventilation information
Shows: Manual Request, Automatic Request, Man. Cancelled,
Waiting for Preconditions, In progress, Passed
011
iGPR Status
Shows the iGPR status
Shows: Normal, Degassing Fail, Flushing Fail, Leak Test Fail,
Inerting Fail, FGSS Prepare Fail, iGPR Gas Trip
012
iGPR Ctrl. State
Shows the iGPR Ctrl. State
Shows: Degassing, Auto Gas Leak Test, Flushing, Gas Rails,
Pressurizing, Gas/Transfer Mode, Inerting, Manual Valve Op-
eration
013
iGPR Mode
Shows the iGPR mode
iGPR Mode:
•
Operational mode
•
Maintenance mode
NOTE:
Use this button only when you have done the related
measures to repair the failure.
014
Pilot Fuel Pressure
Shows the pilot fuel pressure value in bar
015
FGSS Status
Shows the FGSS status
Shows: FGSS status Ready/Not Ready, FGSS Requested,
FGSS Prepare Fail
X72-B
AA00-4618-07AAA-043B-A
Operation Manual
MCP page - GAS SYSTEM
Winterthur Gas & Diesel Ltd.
- 255 -
Issue 003 2021-12