Button
LED
Effect
LOCAL MANUAL CONTROL
Green
Changes from current control to local manual control, during
control transfer the related two green LEDs flash, then the green
LED shows the current control position
NOTE:
The transfer to LOCAL MANUAL CONTROL must be
accepted at the control room console.
ECR REMOTE CONTROL
Green
Changes from local manual control to ECR remote control, dur-
ing control transfer the two green LEDs flash, then the green
LED shows the current control position
ECR MANUAL CONTROL
Green
Changes from local manual control to ECR manual control, dur-
ing control transfer the two green LEDs flash, then the green
LED shows the current control position
BRIDGE REMOTE CONTROL
Green
Changes from local manual control to bridge remote control,
during control transfer the two green LEDs flash, then the green
LED shows the current control position
SAFETY SYSTEM RESET
Red
Sends a request for reset to the engine safety system
When a shutdown is active, the red LED comes on.
SHD OVERRIDE
Red
Overrides the shutdown signals, when the red LED flashes or
comes on constantly
SLOW TURNING FAIL/RESET
Red
Resets a slow turning failure
SOUND OFF-ALM. ACKN.
Green
Sets to OFF the acoustic alarms (bell or buzzer) and changes
alarm indications that flash to alarm indications that come on
constantly
Shows data about the version and does a check of the software
on the display, when you push the button for approximately five
seconds
X72-B
AA00-4618-00AAC-043B-A
Operation Manual
Local control panel - general
Winterthur Gas & Diesel Ltd.
- 280 -
Issue 003 2021-12