PROCEDURE
1
Do a check of the level switch LS3444A (if applicable also LS3445A) for free flow. If
necessary, clean the bore of the pipe of the level switch.
2
Carefully look into the rail unit to find the cause of the leakage.
NOTE:
Possible causes can be a defective pipe to the exhaust valve, a defective flange
or an other defective item.
3
Repair the defective item.
CLOSE UP
•
None
X72-B
AA00-0000-00AAA-311E-A
Operation Manual
Examine the rail unit for leakage
Winterthur Gas & Diesel Ltd.
- 417 -
Issue 003 2021-12