PROCEDURE
1
Cut out the injection of the related cylinder.
NOTE:
If possible, the exhaust valve must always operate.
2
For an engine with direct controlled injection valves, disconnect the electrical connection
from the injection valve.
3
For an engine with conventional injection valves, disconnect the electrical connection from
the injection control unit (ICU).
4
If it is necessary to operate the engine with the injection cut out for an extended period, do
as follows:
4.1
Record the settings of the cylinder oil feed rate.
4.2
Decrease the cylinder oil feed rate for the related cylinder to the minimum setting.
5
Repair the fault as soon as possible, refer to the Maintenance Manual.
CLOSE UP
•
None
X72-B
AA00-0000-00AAA-662A-A
Operation Manual
Temporary cut out a defective injection valve
Winterthur Gas & Diesel Ltd.
- 423 -
Issue 003 2021-12