background image

25

Care & Maintenance

Symptom

HumidiPür™ does

not turn on

Auto Mode is not 

working

Vibrates or makes 

noise

Power cord is hot

Power cord is plugged 
in.
Low Water Indicator 
light is on.

Water is filled inside 
water tank.

Power cord is plugged 
in.

Auto Mode Indicator 
is on.

The unit is located on 
an uneven surface.

Power cord is plugged 
in.

Plug the power cord in.

Fill the water tank

Make sure the water
tank is in place and
filled correctly.

Unplug power cord
and plug it back in.

Push FUNCTION
button to select
Auto Mode.

Move to an even
surface.

Unplug the power
cord and contact
customer support.

Check If:

Solution:

Summary of Contents for HUMIDIPUR AW600

Page 1: ...iple Action Humidifier Model AW600 Read and follow all safety rules and instructions before operating this equipment Please keep this manual for future reference Thank you for purchasing this WINIX product ...

Page 2: ...l fan speed and optimize the humidity level Timer The automatic Timer indicator is used to maintain efficiency throughout the lifetime of the product Sleep Mode Light sensor detects when the room is dark and adjusts the unit to Sleep Mode to reduce power consumption Mist Humidifier HumidiPür generates very fine and light mist to enhance consistent humidity level CleanCel Anti Bacterial Coating Hum...

Page 3: ...oduct Information Installation Operation Troubleshooting Warning Unit Diagram Control Panel Display Selecting a Location Set Up Instructions Modes of Operations Care and Maintenance FAQ Solutions Product Specifications 3 11 12 13 14 15 19 25 27 ...

Page 4: ...ry or property damage Follow these instructions to avoid any risk of personal injury property damage electrical shocks or fire hazard DON T unplug the unit by pulling on it s power cord DON T touch the plug with wet hands DON T bend or place heavy object on the power cord DON T replace or modify power cord If the power cord plug is damaged it must be replaced by the manufacturer or a qualified tec...

Page 5: ...r power outlet with a ground connection DO unplug the HumidiPür when not in use to save on energy consumption DON T plug power cord into loose or damaged electrical outlet This can lead to overheating or electrical shock DON T attempt to repair alter or dissasemble the unit DON T operate the unit if standing water is present ...

Page 6: ...mable material such as gas aerosols or benzene Attempt to change the bucket and refill with clean water every day DON T spray liquids directly into air washer DON T place the unit on an unstable place such as a table or a sink DON T pour water into the top of the air unit place in water tank as directed Note ...

Page 7: ...ert ANYTHING into the air inlet or outlet DON T remove the water tank if a child is nearby DON T install the unit in the place full of high humidity or dust DO unplug the unit and contact your service dealer if it is sunken under water DON T place anything around the unit to allow children to play or sit on ...

Page 8: ...k DON T insert anything into the air inlet or outlet DON T place hands or any body parts near the air outlet during operation DON T place the unit near curtains or other materials that can block the vents of the unit DO unplug the unit and contact your service dealer if any irregular noise or smoke occurs DON T place the unit near a heat source DON T strike or drop the unit 7 Note ...

Page 9: ...DON T lift the unit by the top DON T install the unit under direct light DON T place clothes and towels on top of air washer while operating DO clean Antibacterial disk regularly with warm tap water and allow to air dry DON T use flammable material such as benzene or alcohol to clean the unit DON T spray liquids directly into HumidiPür during cleaning ...

Page 10: ...to stay in the water tank for a long time while not in use DON T install the unit whose airflow outlet is facing the wall DON T drink the water left in the water tank or give it to plants or animals After cleaning allow Antibacterial Discs water tank and pre filter to air dry completely DON T operate the unit while water tank is damaged DON T put the unit near a microwave oven or TV Note ...

Page 11: ...with water still in the water tank DO unplug the unit and move its water tank when water is removed DO clean the air washer regulary with a microfiber towel or any other clean wiping material DON T plug in if the power plug is touched with water DON T put magnet or metal material on the top of the unit DO use clean tap water without detergent soap chemical compounds or hot water over 104ºF Note ...

Page 12: ...eanCel Anti bacterial Disc Handle Water Level Indicator Anti bacterial Water Tank CleanCel Water Tank Release Lever Control Panel Display Air Outlet Cover Air Outlet Fan inside Air Outlet Release Button HEPA Carbon Comination Filter Air Intake Power Plug ...

Page 13: ...y Green Comfort Zone Power Timer Indicator Timer Setting Button Low Water Indicator Mode Indicator PlasmaWave ON OFF Indicator Control Panel Lock Indicator High Humidity Indicator Low Humidity Indicator Fan Speed Indicator Fan Speed Button Low Medium High PlasmaWave ON OFF Indicator PlasmaWave ON OFF Button Humidity Level Indicator Displays humidity level when desirable level of humidity levels ar...

Page 14: ...use defects HumidiPür must be installed and operated on an even surface Vibrations and noise can occur on soft or non flat surfaces Product must be Installed approximately 10cm 4 inches away from the wall and 30 40cm 15 inches from other electronic appliances Before operating the HumidiPür remove any plastic bags and polyfoams from outside and inside the unit ...

Page 15: ...the inside of water tank 3 Replace the water tank by sliding it back into the unit until you hear it click into place 4 Gently slide down the front panel and make sure that it is seated properly and lines up correctly Make sure to unplug the power cord before filling the unit with water We recommend using filtered water to prolong the life of the product Use cautions when moving the unit filled wi...

Page 16: ...wer outlet Push the POWER button The unit will start on AUTO MODE and the PlasmaWave function will be ON A soft buzzing or clicking sound may occur during operation if this is uncomfortable you can turn off the PlasmaWave feature by using the PlasmaWave ON OFF button ...

Page 17: ...ter than 60 the unit will operate at Low fan speed CLEANING DISCS When ambient humidity is sensed at greater than 75 humidity the cleaning discs will stop spinning When ambient humidity is sensed less than 60 the disc resumes to circulate Push the FUNCTION button to select Continuous Mode Continuous Mode Indicator will illuminate The FUNCTION button will cycle the unit between the following Auto C...

Page 18: ...cle the unit between the following Auto Continuous Sleep During Sleep Mode the unit will set fan speed to lowest setting and the display will turn off except for the low fan speed indicator Push the FAN SPEED button to change the Fan Speed The FAN SPEED button will cycle the unit between the following Low Med High ...

Page 19: ...ring Humidification process The TIMER button will cycle through the unit timer settings 2 hours 4 hours 8 hours Push PLASMAWAVE LOCK button to operate PlasmaWave During PlasmaWave operation only Use this button to turn PlasmaWave function ON OFF Push PLASMAWAVE LOCK button to operate PlasmaWave while the unit OFF Use this button to turn PlasmaWave function ON OFF without using the humidification f...

Page 20: ...ully remove it Remove the used water left in the water tank and dispose of it in an appropriate manner Refill water tank with clean water Replace the water tank with a snap Gently slide down the front panel to close Be sure to change water frequently to ensure optimal functioning of the unit Be sure to replace the water tank correctly in order to ensure that the unit functions properly ...

Page 21: ...unplug if not operating for more than 2 days Clean the outside of the unit with a soft cloth and mild detergent Wipe clean with a dry cloth Use the tab on the back cover grille and pull up on the Combo Filter To clean the back cover grille rinse lightly under warm water and air dry After cleaning and letting air dry slide the HEPA Carbon Filter back into it s original location and replace the back...

Page 22: ...reater than 176O F Care Maintenance Cleaning Anti bacterial Discs Be sure to clean the Anti bacterial Discs once a week Clean Anti bacterial Discs with warm tap water and a light detergent Fill warm tap water with detergent in the water tank Clean inside of the cycled Anti bacterial Discs thoroughly 21 ...

Page 23: ...r Disc by turning it counterclockwise Rinse Antibacterial Disc with warm tap water and a mild detergent Clean the inside of water tank with a soft cloth and mild detergent After cleaning assemble the parts Gear Disc Discs and Saw Tooth Gear Disc in the opposite order Gear Disc Disc Plate Saw Tooth Gear Disc Disc Plate Axis inside Disc ...

Page 24: ...cloth and mild detergent 1 2 3 4 Place CleanCel Anti bacterial Discs back into the water tank aligning with grooces and with handle laid flat Replace the Water Tank with a snap Gently slide down the front panel to close the unit Make sure that it is seated properly and lines up correctly ...

Page 25: ...flat tip screw driver at the rear of the unit and remove top cover Holding fan turn fan cap clockwise Rinse fan and fan cap with warm tap water with detergent Remove dust near airflow inlet of the unit by using vacuum cleaner or soft brush After cleaning replace fan and fan cap ...

Page 26: ...e water tank Power cord is plugged in Auto Mode Indicator is on The unit is located on an uneven surface Power cord is plugged in Plug the power cord in Fill the water tank Make sure the water tank is in place and filled correctly Unplug power cord and plug it back in Push FUNCTION button to select Auto Mode Move to an even surface Unplug the power cord and contact customer support Check If Soluti...

Page 27: ...ock mode is on HumidiPür is being used where strong odors and or dust is present Water is left inside the water tank Change to tap water Use 68 F to 77 F temperature water Change to high fan speed Push Plasma Child Lock button for 3 seconds to turn OFF Child Lock mode Replace the water in the water tank and change water more frequently Clean water tank and CleanCel Anti bacterial Discs Refill the ...

Page 28: ... Specifications Model No Power Supply Power Consumption Humdiifying Capacity Tank Max Full Weight Dimensions AW600 120V 60 Hz 16W 3 17 gallons per day 1 3 gallons 1 85 gallons 15 4 lbs 13 4 x 17 7 x 13 4 ...

Page 29: ...Notes ...

Page 30: ...f wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract Th...

Reviews: