Installation manual
blueChip Reader BC TI and BC TE
blueSmart Reader BS TI and BS TE
Einbauhinweise
If several readers are being installed, then
a minimum distance of at least 20 cm
must be maintained between readers.
If inductive loads are switched, then a
quenching diode must be installed paral-
lel to the load for protecting the contacts.
If the supplied cable is shortened or
lengthened, then the reading range of the
reader may be negatively influenced.
Grounding adapter between potential
earth (PE) and V1 or V2 for protection
from extraordinarily high interference
voltage.
Connection to a higher voltage will cause
the destruction of the reader. It is recom-
mended to use a regulated power supply,
which provides an output voltage of 12 V.
In a voltage-free condition of the reader,
no contact exists between „NC“ and
„COM“.
Mounting, programming and disassembly
may only be performed by specialised
staff according to IEC 62368-1.
It is recommended to provide a turn-off
device for the power supply.
Disposal
Environmental damage caused
by electronic components that
are improperly disposed of!
Technical data and connection allocation
Supply voltage at V1 and V2:
8 V bis 16 V DC oder AC 50 Hz
(Limited power source max. 8 A; max. 100VA)
Relay connection NO
= normal open, operating side
Relay connection NC
= normal closed, non-operating side
Relay connection COM
= common, middle pin
Switch. current/switch. volt. max.:
1 A/30 V
Power consumption at 12 V DC:
80 mA
Protection class:
Siedle: IP 54
Gira and bticino: IP 20
Temperature range:
Bx TE antenna unit: -25 °C to +60 °C,
Control unit: -10 °C to +55 °C
Bx TI: -10 °C to +55 °C
Reading interval with key:
typically 10 mm
Reading interval with card:
typically 40 mm
Assembly:
preferably in standard flush mounted box (UP55)
or surface-mounted box combined with a suitable
switch design ( e. g. Gira, Siedle, bticino)
AC / = DC
AC / = DC
Wiring Bx TE
1
2
3
4
5
11
12
13
14
15
16
Cable length 3.0 m, 3 pairs, stranded
Contact shown in the open position
Antenna unit of Bx TE
Only with readers that have a separated antenna
Control unit Bx TE
Buzzer
AN- grey lead
AN+ pink lead
GND white lead
LDR brown lead
LDG green lead
SUM yellow lead
Relais
Power V1
Power V2
Relay NO
Relay NC
Relay COM
Connection on direct-current (DC)
or alternating-current (AC)
grounding adapter
ground
Green LED
Red LED
YellowLED Buzzer
Display of system status
Normal state, continuous release inactive
Normal state, continuous release active
Behaviour in the event of a normal state entry
Authorised key
200 ms
Unauthorised key
750 ms
Authorised key (continuous release active)
12 ms
Unauthorised key (continuous release active)
12 ms
Activation of continuous release
2 x 200 ms
Deactivation of continuous release
(Red LED blinks along with a buzzer signal, after that yellow LED blinks)
2 x 750 ms
Display of an error condition
This condition leads to the deactivation of the continuous release
Error clock time, continuous release inactive
Error time, continuous release active
Behaviour in the event of a transaction during an error state
Error
No transaction is possible in this state
Error time
Alternating with the signalling of a normal transaction
10 x 50 ms
Behaviour during a programming procedure
3 ms yellow LED signal after each received data frame
750 ms
– It is forbidden to dispose of the prod-
uct with household waste, the disposal
must be performed according to the
regulations. Therefore, dispose of the
product in accordance with European
Directive 2012/19/EU at a municipal
collection point for electrical waste or
have it disposed of by a specialist com-
pany.
– Commercial customers can optionally
return the product to Aug. Winkhaus
GmbH & Co. KG, Entsorgung/Verschrot-
tung, Hessenweg 9, 48157 Münster.
Wiring Bx TI
Bx TI/TE: LED and buzzer signals
1
2
3
4
5
MP
L
MP
L
Reader Bx TI
Power V1
Power V2
Relay NO
Relay NC
Relay COM
Contact shown in the open position
Relay
Buzzer
230 V AC
12 V AC
grounding adapter
ground
Reader Bx TI
Wiring during closed-
circuit operation
Power V1
Power V2
Relay NO
Relay NC
Relay COM
recovery diode
bipolar
recovery diode
bipolar
door opener
12 V AC
door opener
12 V AC
230 V AC
12 V AC
grounding adapter
Conformity
Aug. Winkhaus GmbH & Co. KG herewith
declares that the device is compliant with
the basic requirements and the relevant
rules of the directive 2014/53/EU. The
complete version of the EU declaration of
conformity is available at:
winkhaus.com/konformitaetserklaerungen
LED on
LED blinks
Z
O MW 09
20
20 Print-no
. 99
7 000 225 All rights, including the right of alt
er
ation, ar
e r
eserv
ed.
ground