Installation manual

blueChip Reader BC TI and BC TE
blueSmart Reader BS TI and BS TE

Einbauhinweise

If several readers are being installed, then 
a minimum distance of at least 20 cm 
must be maintained between readers. 
If inductive loads are switched, then a 
quenching diode must be installed paral-
lel to the load for protecting the contacts. 
If the supplied cable is shortened or 
lengthened, then the reading range of the 
reader may be negatively influenced. 
Grounding adapter between potential 
earth (PE) and V1 or V2 for protection 
from extraordinarily high interference 
voltage. 
Connection to a higher voltage will cause 
the destruction of the reader. It is recom-
mended to use a regulated power supply, 
which provides an output voltage of 12 V. 
In a voltage-free condition of the reader, 
no contact exists between „NC“ and 
„COM“. 
Mounting, programming and disassembly 
may only be performed by specialised 
staff according to IEC 62368-1.
It is recommended to provide a turn-off 
device for the power supply.

Disposal

Environmental damage caused 
by electronic components that 
are improperly disposed of!

Technical data and connection allocation

Supply voltage at V1 and V2: 

8 V bis 16 V DC oder AC 50 Hz

 

(Limited power source max. 8 A; max. 100VA)

Relay connection NO  

= normal open, operating side   

         

Relay connection NC  

= normal closed, non-operating side   

          

Relay connection COM  

= common, middle pin

Switch. current/switch. volt. max.:  

1 A/30 V

Power consumption at 12 V DC:  

80 mA

Protection class: 

Siedle: IP 54

 

Gira and bticino: IP 20

Temperature range:  

Bx TE  antenna unit: -25 °C to +60 °C,

 

 

Control unit: -10 °C to +55 °C

 

Bx TI: -10 °C to +55 °C

Reading interval with key: 

typically 10 mm

Reading interval with card: 

typically 40 mm

Assembly:  

preferably in standard flush mounted box (UP55)  

 

or surface-mounted box combined with a suitable  

 

switch design ( e. g. Gira, Siedle, bticino)

AC / = DC
AC / = DC

Wiring Bx TE

1
2
3
4
5

11
12
13
14
15
16

Cable length 3.0 m, 3 pairs, stranded

Contact shown in the open position

Antenna unit of Bx TE

Only with readers that have a separated antenna

Control unit Bx TE

Buzzer

AN-   grey lead
AN+   pink lead
GND   white lead
LDR   brown lead
LDG   green lead
SUM   yellow lead

Relais

Power V1
Power V2
Relay NO
Relay NC
Relay COM

Connection on direct-current (DC) 

or alternating-current (AC)

grounding adapter

ground

Green LED

Red LED

YellowLED Buzzer

Display of system status

Normal state, continuous release inactive

Normal state, continuous release active

Behaviour in the event of a normal state entry

Authorised key

200 ms

Unauthorised key

750 ms

Authorised key (continuous release active)

12 ms

Unauthorised key (continuous release active)

12 ms

Activation of continuous release

2 x 200 ms

Deactivation of continuous release 
(Red LED blinks along with a buzzer signal, after that yellow LED blinks)

2 x 750 ms

Display of an error condition

This condition leads to the deactivation of the continuous release

Error clock time, continuous release inactive

Error time, continuous release active

Behaviour in the event of a transaction during an error state

Error

No transaction is possible in this state

Error time

Alternating with the signalling of a normal transaction

10 x 50 ms

Behaviour during a programming procedure

3 ms yellow LED signal after each received data frame

750 ms

–      It is forbidden to dispose of the prod-

uct with household waste, the disposal 
must be performed according to the 
regulations. Therefore, dispose of the 
product in accordance with European 
Directive 2012/19/EU at a municipal 
collection point for electrical waste or 
have it disposed of by a specialist com-
pany.

–     Commercial  customers  can  optionally 

return the product to Aug. Winkhaus 
GmbH & Co. KG, Entsorgung/Verschrot-
tung, Hessenweg 9, 48157 Münster. 

Wiring Bx TI

Bx TI/TE: LED and buzzer signals

1
2
3
4
5

MP

L

MP

L

Reader Bx TI

Power V1
Power  V2
Relay   NO
Relay   NC
Relay   COM

Contact shown in the open position

Relay 

Buzzer

230 V AC

12 V AC

grounding adapter

ground

Reader Bx TI

Wiring during closed-
circuit operation

Power V1
Power  V2
Relay   NO
Relay   NC
Relay   COM

recovery diode

bipolar

recovery diode

bipolar

door opener

12 V AC

door opener

12 V AC

230 V AC

12 V AC

grounding adapter

Conformity

Aug. Winkhaus GmbH & Co. KG herewith 
declares that the device is compliant with 
the basic requirements and the relevant 
rules of the directive 2014/53/EU. The 
complete version of the EU declaration of 
conformity is available at:
winkhaus.com/konformitaetserklaerungen

LED on

LED blinks

Z

O MW 09

20

20   Print-no

. 99

7 000 225 All rights, including the right of alt

er

ation, ar

e r

eserv

ed.

ground