43
Installation, Operating and
Maintenance Instructions
No. Name
MUST!
Manda-
tory *
Available
as on
accessory
or as on
option
Supplied
by
customer/
not
included
in delivery
Power supply unit
X
Input emergency power control
Notice!
Without battery, connect to + 24 V!
** Cable (min. 4 x 0,8 mm
2
, max. 50 m
Length) power supply
X
X
** Cable (min. 4 x 0,8 mm
2
, max. 1 m
Length) emergency power supply
X
X
Battery, T-HT AKKU MIT LADESCHALTUNG
X
Antenna (mounting on the outside)
X
9.1
Antenna cable, custom-manufactured,
2,5 m fixed to antenna, cable ends with
wire end sleeve
Notice!
You may shorten the cable but
not extend it!
(longer cable, no warran-
ty for function)
Customer-specific ACS
X
External control unit
X
X
11.1
** Sash cable of the cable transition
"T-KÜ-T1 FT ..." or "T-Connection
cable 6 m ..." from the motor housing
to the external control unit, cable ends
with wire end sleeve or plug for the
motor housing
Notice!
Do not extend the cable! Grey
and pink wire must be insulated!
(longer cable, no warranty for function)
11.2
Plug for motor housing
11.3
Reset button of the error counter
11.4
Plug RS / LS optional for use as reset
button of the error counter (parallel
to
11.3
)