Aug. Winkhaus GmbH & Co. KG
∙ Hessenweg 9 ∙ 48157 Münster ∙ T +49 251 4908 - 0 ∙ zutrittsorganisation@winkhaus.de ∙ www.winkhaus.de
ETB-IM
16
Operating manual
9.6 Saving of locking events
The preset release time set at the factory is 3 seconds. This can be modified
via the blueControl software and programmed in the component via the
programming device BCP-NG or BXP BS, the blueSmart Active key or via
the optional Winkhaus virtual network.
One permanent release mode per electronic door handle can be
parametrised via the management software.
The electronic door handle supports all permanent release modes that can
be set in the blueControl management software:
• OFF: no permanent release can be set.
• Manual: Can only be switched on and off manually.
• Auto ON / Auto OFF - no manual intervention: The permanent release can
not be switched on and off manually. The switch-on and switch-off always
takes place according to the specified values.
• Auto ON / Auto OFF - manual intervention within time profile: Permanent
release switches on and off automatically according to the specified
values. Manual override until the next switching via authorised
identification medium within the time profile.
• Auto ON / Auto OFF - unlimited manual intervention: Permanent release
switches on and off automatically according to the specified values.
Manual override until the next switching via authorised identification
medium regardless of the key time profile.
• Auto ON / Auto OFF - manual intervention within time profile: Permanent
release is only switched on manually. Permanent release can be
deactivated within the time profile. Automatic switch-off takes place at
the Auto OFF switching time.
• Auto ON / Auto OFF - unlimited manual intervention: Regardless of the
key time profile, permanent release can be switched on and off at any
time. Automatic switch-off takes place at the Auto OFF switching time.
• Manual ON / Auto OFF relative: Permanent release is only switched on
manually. Permanent release can be deactivated within the time profile.
Automatic switch-off takes place at the relative Auto OFF switching time
(e.g. 60 minutes since permanent release was switched on).
For programming the ETB-IM the blueControl Professional from version
4.6.2.0 or the blueControl Start / blueControl Start virtual from version 5.7 is
required.
Authorised and unauthorised access attempts with identification media
belonging to the system are logged in the event memory with the date, time
and the number of the identification medium. The electronic door fitting has
a ring memory, which logs the last 2,000 locking events. The settings for the
logging function and/or the event transport via the optional Winkhaus
virtual network can be managed via the blueControl software.
9.5 Permanent release modes
9.4 Release time