background image

 

 

31 

Chapter 4: Operating the Device 

3. 

Check the status color of the 

Barcode

 icon. 

Item 

Status Color 

Description 

 

Barcode

 

Orange 

Barcode Reader is enabled. Reading will need to be 
triggered manually thru Fn button. 

White 

Barcode Reader is disabled. 

 

4. 

Open the application where barcode reader will be displaying the scanned barcode. 

5. 

Trigger the barcode reader by pressing Fn2 function key. 

 

Tap 

Disconnect

 button to stop the connection with Barcode Reader. 

*To recover the connection, please tap on the button again to re-connect with Barcode Reader. 

4.4.6.1 Device Configuring and Setting 

1.Click on Windows 

 

 and search for 

EZConfig-Scanning

 from the Start menu. 

 

2.Click on 

EZConfig-Scanning v4_IE

 and allow the blocked content if browser is blocking the content. 

3

.Click on “Connected Device” icon and wait for system to discover the device (Honeywell N660X). 

Summary of Contents for M101P-ME

Page 1: ...ons carefully before using this product and save this manual for future use M101P ME Medical Windows Tablet Intel Apollo Lake Pentium N4200 Windows 10 IoT Enterprise User Guide Document Version 1 1 Do...

Page 2: ...ireless LAN Wi Fi 28 4 4 2 Using the Wireless WAN 3G LTE 29 4 4 3 Using the GPS 29 4 4 4 Using the Bluetooth 29 4 4 5 Turning On Off LED Indicators 30 4 4 6 Using the Barcode Reader 30 4 4 7 Using the...

Page 3: ...rst CHAPTER 6 ACCESSORIES 64 6 1 ACCESSORIES INTRODUCTION 65 6 2 INSTALLING VEHICLE CRADLE 66 APPENDIX 68 APPENDIX A MEANING OF SYMBOLS ON THE UNIT 68 APPENDIX B TECHNICAL SPECIFICATIONS 69 APPENDIX C...

Page 4: ...al Windows Tablet M101P ME User Guide Chapter 1 Read Me First This chapter provides safety information handling and maintenance precautions and other important information about using the M900P rugged...

Page 5: ...potentiel Warning An Electrical Shock Warning indicates the potential harm from electrical hazards and how to avoid the potential problem Avertissement Un Avertissement de Choc lectriqueindique le pot...

Page 6: ...y is not charged using one of the specified methods electrolyte leakage generation of heat ignition or rupture may result FR Ne pas charger la pile par d autres m thodes que celles sp cifi es dans ce...

Page 7: ...tandards i e IEC 60601 1 for medical equipment Furthermore all configurations shall comply with the system standard in IEC 60601 1 Anyone who connects additional equipment to the signal input part or...

Page 8: ...er votre prise obsol te Use only accessories specified by the manufacturer FR Utiliser uniquement les accessoires sp cifi s par le fabricant This product should not be used near water such as bathtubs...

Page 9: ...r essuyer l ext rieur du produit Gently wipe the display with a soft lint free cloth Do not use alcohol or detergent on the product FR Essuyer d licatement l cran avec un chiffon doux non pelucheux Ne...

Page 10: ...ommunications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at him own expense CE Notice...

Page 11: ...11 Chapter 2 Getting Started Chapter 2 Getting Started This chapter tells you step by step how to get the Rugged Tablet up and running...

Page 12: ...ed features a crystal clear 1920 x 1200 resolution display projected capacitive touch screen barcode scanner and superior processing power coming from Intel s Apollo Lake processor this tablet can be...

Page 13: ...facturer PHINO ELECTRIC HUIZHOU LTD Model name PHP 350 TO PHS 301 Capacitive Touch Stylus Manufacturer HuntWave Industrial Co Ltd Model name 3 5mm Plastic pen tip and 5 5mm Rubber stylus Driver CD Opt...

Page 14: ...tton Programmable function key configured by Hottab Utility 7 Menu Button Hottab Quick Access 8 Power Button Power on off tablet Front LED Indicator Details No Item Description 9 Micro HDMI HDMI outpu...

Page 15: ...aded 23 Speakers Emit sounds 24 3G LTE Module SIM card slot Service window to insert Micro SIM card Also provide access to 3G LTE Module 25 Fn2 Button Programmable function key configured by Hottab 26...

Page 16: ...Left In Windows Buttons Keystroke Menu Hottab Quick Access Fn1 Default Web Browser Fn2 Default Camera UP Up Down Down Power Power ON OFF Up Down Ctrl Alt Del LED Indicators Item Description Power Indi...

Page 17: ...dow Remove the one screw that secures the 3G LTE module Carefully lift the module up Do not to damage the connected cables Carefully flip and move the 3G LTE module and to the right Do not disconnect...

Page 18: ...ttery Release Slider that is spring loaded Pull back and hold 5 Lift the battery out using the opening on the side of battery compartment 2 5 3 Charging Your Tablet The M101P ME Medical Tablet Compute...

Page 19: ...ering on the device for the first time please make sure there s no interruption during the Windows setting up process for example accidentally powering off If it happened please access the recovery me...

Page 20: ...20 Medical Windows Tablet M101P ME User Guide Chapter 3 Setting Up Windows This chapter details how to setup the Windows that may be installed on the tablet for the first time...

Page 21: ...nize all the computers on the network For example you are in a coffee shop or airport or you have mobile broadband This is a public network and is not trusted Select the location where you will most o...

Page 22: ...will then try to connect to network Tap Skip this step to continue without a wireless connection as you can then set up the network later 5 On the Get going fast screen click Use Express settings for...

Page 23: ...ssword and Password hint in the fields provided then tap Next 7 The initial setup screens are complete and the desktop is displayed 8 Read any introductory screens describing features of your computer...

Page 24: ...Medical Windows Tablet M101P ME User Guide Chapter 4 Operating the Device This chapter describes how to operate the M101P ME Tablet Computer including camera Hottab barcode RFID WWAN WLAN GPS feature...

Page 25: ...F RFID reader Barcode reader and UHF RFID reader are optional module please make sure user have ordered the module before using the SDK As Windows starts up Hottab starts and runs in the background To...

Page 26: ...offers 8 empty slots to store user s desired quick access Shortcuts can be mapped to any of the executable files exe installed on the tablet Short Cut Menu To store a new shortcut 1 Open the Hottab ut...

Page 27: ...e Camera is disabled white tap on the Camera icon to enable it orange 5 Go back to the Hottab main menu by pressing the Menu Button OR click on the back arrow on top 6 Tap on the Camera icon to open C...

Page 28: ...status color of the Wi Fi icon Item Status Color Description Wi Fi Orange Wi Fi is enabled White Wi Fi is disabled 4 If the Wi Fi feature is disabled white tap on the Wi Fi icon to enable it orange 5...

Page 29: ...encompassed the better the signal is 4 4 3 Using the GPS To enable the GPS 1 Open the Hottab utility by press the Menu Button located on the front panel OR launching the Hottab Utility application 2...

Page 30: ...2D 1D Barcode Reader is optional for M101P ME Tablet PC and is not re workable by the end user To use this feature please make sure the tablet PC is built in barcode reader before use Caution Use of...

Page 31: ...ode 5 Trigger the barcode reader by pressing Fn2 function key Tap Disconnect button to stop the connection with Barcode Reader To recover the connection please tap on the button again to re connect wi...

Page 32: ...32 Medical Windows Tablet M101P ME User Guide 4 Once Honeywell N660X is discovered please click Configure Device button as shown...

Page 33: ...nning mode Settings 1 Click on Device Settings under the Input Output settings section 2 Select the desire scanning mode from the drop down menu shown as below 3 After selecting a desire scanning mode...

Page 34: ...rly Streaming Presentation Mode When in Streaming Presentation mode the scan engine s aimer goes out after a short time but the scan illumination remains on all the time to continuously search for bar...

Page 35: ...TA 2 5 Disable Code 2 5 Disable Codabar Enable Code 93 Enable Code 11 Disable MSI Disable Telepen Disable Trioptic Code Disable Postal Code Disable Planet Code Disable Korea Psot Disable China Post Di...

Page 36: ...disconnect with system after clicking the reset to default button If the Disconnection happened please scan barcodes below in the following steps Step 1 Frist please scan the USB HID barcode Step 2 Th...

Page 37: ...Formatting icon 2 Click on Editor button under the Prefix or Suffix section and create Prefix Suffix value by typing in the block or select desire characters in the Control chars Printable chars and E...

Page 38: ...use this feature please make sure the tablet PC is built in HF RFID reader before use or contact our sales contact window for more details Note User can download the SDK from Winmate Download center...

Page 39: ...e ON button 5 Check the status color of the ON icon is green and the status color of the RFID icon on the Hottab menu is orange at the same time Item Status Color Description RFID Orange HF RFID Reade...

Page 40: ...s be ready to scan tags 1 When the RFID tag is detected from RFID antenna the data will be read automatically 2 User can define the RFID scanning frequency from the drop down menu shown as below The f...

Page 41: ...ta Two options are available Keyboard Wedge Under this setting the data scanned is sent like keyboard data The scanned data can be output directly to the demo area below this window or user can also o...

Page 42: ...fines to append an TAB which is followed by the characters Regex Filter Press on Presets button user can define how many characters to show after the data scanned Replace User can define specific char...

Page 43: ...nector To work with external GPS antenna please make sure the tablet PC is well installed to vehicle dock and the vehicle dock has connected with external GPS antenna When working with vehicle dock co...

Page 44: ...the touchscreen rejects false inputs from liquid drops When the liquid is removed the touchscreen accepts touch inputs from bare fingertips Supports input by Active stylus with palm rejection Rubber t...

Page 45: ...ault setting of the touch screen supports multi touch mode up to 10 points 4 4 10 2 Switch via Programmable Function Buttons To switch between the different touchscreen modes via the programmable func...

Page 46: ...the items listed in Settings Menu 4 5 1 PC Information This section provides user device information in regards to BIOS Version EC Versions Hottab Versions OS Versions as well as Unit Serial Number s...

Page 47: ...ap on the Setting button 3 Tap on function key icon for the corresponding key that you want to change 4 At top of utility it will say Short Press or Long Press to indicate what type of press is being...

Page 48: ...E User Guide Chapter 5 Frequently Used Settings This chapter frequently used settings such as changing resolution and scaling using recovery wizard docking connector and D Sub port description also co...

Page 49: ...olution setting at 1920 x 1200 This section will explain how you can adjust the built in windows display scaling setting and resolution setting Note The M101P ME Medical Tablet computer is shipped wit...

Page 50: ...0 Recommended or any other desired display scaling 5 1 2 Changing Screen Resolution Alternatively instead of changing the display scaling setting user may choose to change the overall resolution setti...

Page 51: ...y Settings prompt will show up to ask the user if the applied resolution is usable 4 If the new resolution is the desired display setting hit Keep changes and continue to next step If the new resoluti...

Page 52: ...artment 5 Pen Hottab to check Main battery level If the battery level is displayed incorrect check if the new removable battery is inserted properly 6 If the battery level displayed correct continue u...

Page 53: ...creen shows the Recovery Wizard Click on Recovery button to continue 4 A warning message about data loss will show up Make sure data is backed up before recovery and click on Yes to continue 5 Wait ti...

Page 54: ...NC 16 USB 7 NC 17 GND 8 DETECT 18 GND 9 Power 19 DETECT 10 Power 5 5 COM Port Definition The M101P ME Medical Tablet Computer uses Hottab utility for built in peripherals control All the COM port numb...

Page 55: ...t click on the COM number need to be changed and tap on Properties to open the setting page 2 Tap on Port Setting tab and click on Advanced button 3 Tap on the dropdown list and choose the correct COM...

Page 56: ...uickly establish Bluetooth connection with the computer It is encoded with leading characters to instruct the wireless Bluetooth barcode scanner to initial Bluetooth Serial Port Profile pairing reques...

Page 57: ...57 Chapter 5 Frequently Used Settings 3 Once the Bluetooth other devices Menu appears click More Bluetooth options under Related settings section as shown below Click OK to continue...

Page 58: ...ces to find this computer as shown below Click OK to continue 5 In the Bluetooth Settings menu go to COM Ports tab COM port has to be setup for the wireless Bluetooth Barcode Scanner to communicate vi...

Page 59: ...e user has to configure the application that is used to accept the scanned data from the wireless Bluetooth Barcode Scanner The application has to be configured to accept the same COM Port that has be...

Page 60: ...indow pop up on the right hand side of the desktop Left click on the mouse to enter Add a device menu 3 Locate the Bluetooth icon in the Notification Area 4 Click Add Bluetooth Device 5 In Add a Bluet...

Page 61: ...lly pared to the Computer follow the steps below 1 Locate the Bluetooth icon in the Notification Area Select Show Bluetooth Devices You can access this menu in the Control Panel Windows Control Panel...

Page 62: ...me for every wireless LAN device in the network Restart the tablet computer Make sure the IP address or subnet mask setting is correct I cannot connect to another device with Bluetooth Make sure that...

Page 63: ...sure the barcode code type is enabled in the tablet To enable disable a specific barcode code type go through the Barcode Scanner Configuration section I am having GPS accuracy issue When utilizing t...

Page 64: ...64 Medical Windows Tablet M101P ME User Guide Chapter 6 Accessories This chapter lists available accessories and describes how to install accessories to M101P ME medical tablet computer...

Page 65: ...8K000A0003L Use to mount tablet in a vehicle Battery Charger 98KT00A0000F Use to charge tablet s battery Active Pen 98K000A0007D Use for data input on a screen Smart Card Reader 98K000A0003U Use to re...

Page 66: ...l Block x 1 Specifications Driver installation For the tablet to work with the Cradle the driver of the Cradle has to be installed first The Cradle driver is not pre installed on the tablet For a deta...

Page 67: ...sideways The top hook should be released after the latch is pulled Tilt the tablet slightly forward first and then pull the tablet straight up to remove it The Cradle s input output expansion functio...

Page 68: ...is compliance with Part 15 of FCC rules Class A Serial number This way up Stacking limit by number Direct current Fragile Weight Keep away from rain Temperature limits Recycling symbol for corrugated...

Page 69: ...ata Capture Barcode Optional 1D 2D Barcode Reader RFID Optional HF RFID reader 13 56 MHz Security Function Security Password security for user and hard disk lock Trusted Platform Module TPM 2 0 MDM SO...

Page 70: ...formation M101P ME medical tablet available for order in the following configurations Order Information 3G 4G 1D 2D Barcode Reader HF RFID M101P ME Optional N A N A M101P MEHF Optional N A Default M10...

Page 71: ...___________________________________________________________ _____________________________________________________________________________________ ______________________________________________________...

Page 72: ...Winmate Inc 9F No 111 6 Shing De Rd San Chung District New Taipei City 24158 Taiwan R O C www winmate com Copyright Winmate Inc All rights reserved...

Reviews: