SECTION 4 –
APPLIANCES AND SYSTEMS
4-6
NOTE: Some models may be equipped with a
Water Pump switch in the water service
center on the outside of the coach or
within the bathroom area for your
convenience.
WATER HEATER – GAS
TANKLESS
–If Equipped
The Gas Water Heater operates from propane
gas.
See the Water Heater manufacturer’s
operation manual provided in your InfoCase for
complete operating instructions, safety
warnings, and maintenance information before
operating the Water Heater.
1. Turn the Water Heater Power switch (located
inside the water heater door) to the ON
position.
2. Press the Water Heater LP switch to ON. The
monitor panel display will indicate that the
heater is “On”. If the monitor panel display
reads “Water Heat LP Fail”, it means that the
burner has gone into “lockout” mode and must
be restarted. If this happens, turn the Water
Heater LP switch off for about 5 minutes, then
turn it back on.
3. Set the Gas Modulating Dial to the
appropriate setting.
•
Normal Weather - Set dial to the middle area.
•
Extreme Cold Weather - set the dial to the
extreme right area (large flame).
•
Extreme Hot Weather - set the dial to the
extreme left area (small flame).
4. Open a hot water faucet anywhere in the coach
to a normal flow rate. Wait for the water to
travel from the Water Heater to the faucet.
(this may take a few seconds to a minute). If
the Hot water is not Hot enough, turn the Gas
Modulating Dial “clockwise” to increase the
flame/BTUs to raise the Hot Water
Temperature.
Water Heater Power Switch
(Push up to turn ON)
Propane Gas Water Heater Switch
(Located on OnePlace
®
monitor panel)
Gas Modulating Dial
• Turn “clockwise” to increase hot water
temperature.
• Turn “counter-clockwise” to decrease the
temperature.