4-9
SECTION 4 –
APPLIANCES AND SYSTEMS
turn off when the temperature of the air
entering the air conditioner rises a few degrees
above this setting. The internal heat strip will
continue to cycle on and off until the selector
switch is turned to another operation mode.
Check your Air Filter
Closed or blocked vents and a dirty air filter
can hinder the efficiency of a heat strip.
•
Be sure ceiling vents are open to distribute
heat strip output air.
•
The A/C return air filter should be checked
monthly for dirt build-up and cleaned or
replaced as needed. See “Air Conditioner
Filter” elsewhere in this section.
Further Information
See the air conditioning/heat strip
manufacturer’s information in your InfoCase for
complete operating instructions.
ROOF AIR CONDITIONING
SYSTEM
Cooling Operation
•
Turn the selector switch to the “Low Cool” or
“High Cool” position.
•
Rotate the temperature control to the position
that is the most comfortable to you. When the
temperature of the air entering the air
conditioning unit rises a few degrees above
the setting you have selected, the thermostat
will turn the compressor on. When the
temperature of the air entering the air
conditioning unit drops below the selected
setting, the thermostat will turn the
compressor off. When the air conditioner is in
the cooling mode, it will continue to cycle the
compressor on and off until the selector
switch is turned to another operation mode.
•
Position the louvers to the desired direction
the discharge air is to flow.
During Cooler Nights
When outdoor temperatures drop in the
evening or at night below 75 degrees F, the
temperature control needs to be set at midpoint
between “Warmer” and “Cooler”. If the setting is
at “Cooler”, the evaporator coil may become iced
up and stop cooling. During the day when
temperatures have risen to at least 75 degrees F,
reset the thermostat switch to the desired setting.
NOTE: Should icing up occur, it is necessary to
let the evaporator coil defrost before
normal cooling operation is resumed. At
this time, operate the air conditioning
unit in the “High Fan” position with the
system at maximum airflow. When
increased or full airflow is observed, the
evaporator coil should be clear of ice.
Further Information
Refer to the air conditioner manufacturer’s
information in your InfoCase for complete
operating instructions.
AIR CONDITIONER FILTER
The washable foam air conditioner filter is
located in the ceiling-mounted return A/C grille
in the lounge area of the coach.
It is recommended to check the filter monthly
for dirt build-up and cleaned or replaced, as
necessary.