SECTION 10
SLIDEOUT / LEVELING
10-6
Step 2 - Crank the Room Inward
•
A wrench is used to crank the room inward.
You may use the ratchet wrench supplied with
the coach (in one of the storage
compartments) or any type of lug wrench of
the same nut size.
•
Crank-in bolts are located on the outboard
mounting plates of the slideout room as
shown. These plates are located at both ends
of the room inside the StoreMore
TM
compartment doors.
•
Loosen the locking screws at the crank-in bolt
shafts as shown before trying to turn the bolts.
•
After loosening the lock screws, fit the
ratchet wrench onto the bolt head and begin
cranking clockwise slowly a few turns, then
alternate to the other side for a few turns. With
an assistant using an additional wrench, crank
both sides evenly together to speed this
process.
•
Crank the wrench(es) clockwise slowly, until
the room is fully retracted. Allow about 10
minutes to crank room in fully.
NOTE: Attempting to crank the room in too
quickly will raise pressure in the
hydraulic fluid lines and make cranking
more difficult.
Step 3 - Secure Travel Locks/ Straps and
Close Hydraulic Line Valves
•
Latch Travel Straps or activate the slideout
room travel locks.
•
Close the slideout solenoid valves completely.
NOTE: Close the valves snugly, but do not
overtighten. Overtightening may cause
internal damage to the valves.
•
See your dealer for service of the room
extension system before using again.
BEDROOM SLIDEOUT
EMERGENCY RETRACTION
In the unlikely event that your bedroom
slideout fails to retract using the power switch,
check for obvious causes first, such as low charge
Leveling Jack Valves - Do Not Open
Retract Bolt
Lock Screw
CAUTION
The Retract Bolts must be ‘backed out’ to
their original positions immediately after
the crank-in procedure to avoid damaging
the retract bolts and slideout mechanism