13-3
SECTION 13
SLIDEOUT ROOM
14 - SLIDEO
UT R
OOM
13 - SLIDEOUT ROOM
•
After the room has been retracted, refasten
the safety travel straps.
Troubleshooting
Battery Voltage or Circuit Breaker Problems
If the slideout room will not work:
•
The chassis battery may be low on charge.
Press and hold the Aux Start switch on the
dash to the Momentary (MOM) or Boost po-
sition while pressing the slideout control
switch. This momentarily connects the coach
batteries to assist in retracting the room.
•
The circuit breaker may be tripped. The cir-
cuit breaker, labeled ‘Slideout Power’ is lo-
cated on a panel on an interior wall of the
passenger side storage compartment just be-
hind or ahead of the entrance door.
Troubleshooting
Problems Retracting the Room
Set the Park Brake if the red Park Brake light
flashes while pressing the Retract button.
If an error is detected on your DigiSync Room
Slide System, the green LED on the left side of
the control panel will blink an error code. If an
error code appears, see the On Board diagnostics
section to determine the problem. The error code
must be cleared prior to operating the room. To
clear the error, press the “RESET” button with a
small tool such as a toothpick. Before operating
the room after an error has been detected, check
for obvious faults such as obstructions prior to
trying to operate the room again. If the error code
appears again, the room will need to be retracted
using either the manual retraction method or the
fully manual method. Both methods listed below
are intended as a means to retract the room to pre-
pare the coach for travel to the nearest authorized
Service Center.
To retract the room after an error is detected,
you override the synchronization programming
and operate the room in the Manual Mode.
Manual Mode:
Manual Mode lets you individually move the
two room arms by pressing the IN and OUT but-
tons on the control pad.
This mode can be used
only if there is not a motor failure or full electri-
cal system failure.
To override the encoder and
enter the Manual Mode, press and hold the RE-
SET button until the two LEDs begin to flash.
While in the Manual Mode each of the two,
room slide arms are activated by pressing and
holding the IN and OUT buttons. The “OUT”
button will retract the front arm. The “IN” button
will retract the back arm. Both IN and OUT but-
tons may be held down at the same time to simul-
taneously activate both arms to retract the room.
If one side of the room gets ahead of the other, re-
lease that button until the other arm catches up.
The current limiting feature of the control still
functions in the Manual Mode so each side can be
fully retracted until it stops.
Once the room has been retracted, the control
will return to the automatic mode after 60 sec-
onds. You can manually return to automatic
mode by pressing the stop button.
Green light will flash
error code, if system malfunctions*
Diagnostics
Reset Button*
Red light will flash if park
brake not set.
*Not equipped on single mechanism systems
Never let one side get more than 2
inches (50 mm) ahead of the other
while retracting.
CAUTION