background image

                                                                                                                           

RFID Reader

 

 

Picture 14 Multiple inventory Delay time setting 

The setting is for module waiting time after one inventory cycle during the multiple 
inventory working. 

This is only applied for single port module. Default value is 0 

during multiple inventory. At such case, the module will be working at full load, while 
the module temperature will be higher. 

13.

 

Antenna working and interval time setting 

Antenna working and interval time setting is in Basic Setting, as below picture. 

 

Picture 15 Antenna working and interval time setting 

The setting is for each antenna working time and interval time during multiple 
inventory. Before the setting, you should choose the antenna number. 
For instance, if want to set ANT1 of working time 300ms, ANT2 of working time 
350ms, ANT3 of working time 300ms, ANT4 of working time 500ms, and waiting   
1000ms for once reading cycle, see following steps: 
a)

 

Click ANT1, ANT2, ANT3, ANT4, and ‘set’;   

 

b)

 

Set ANT1 of working time 300ms, ANT2 of working time 350ms, ANT3 of 
working time 300ms, ANT4 of working time 500ms, and interval time is 1000ms. 

 

14.

 

Buzzer setting 

Buzzer setting is in Basic Setting as below picture. 

 

Picture 16 Buzzer setting 

Notice: The function is only for HYR830 reader. 

Summary of Contents for HYR830

Page 1: ...User manual HYR830 Winnix Technologies Co Limited ...

Page 2: ...e the motor vehicles z Road and bridge charge as the product is able to read the tag data quickly in long distance road rate and bridge can be charged without stopping Vehicles z Customs management the management for goods to pass and transit the customs and vehicles z Logistics and warehouse Management Goods flow warehouse management and the flowing management of mail parcel luggage z Parking man...

Page 3: ...uency interval 250KHz 6 Channel bandwidth 250 KHz 7 Frequency hopping speed 2 s 8 Maximum power output 30 dBm 9 Step interval 1 dB 5 30dBm adjustable by software 10 Label protocol EPC C1G2 ISO18000 6C 11 Radio frequen cy power rising time 500 μs 12 Radio frequency power dropping time 500 μs 13 Adjacent channel power leaking ratio 40 dB 1CH 60 dB 2CH 14 Frequency stabilizing ratio 10 ppm 25 40 20 p...

Page 4: ...RFID Reader Picture1 Front view ...

Page 5: ...RFID Reader External Interface ...

Page 6: ...ation 5 WIEGAND1 Output WIEGAND 6 485A Bidirection RS485 7 GPIO1 Output Optical isolation 8 GPIO4 Output Optical isolation 9 GPIO5 Input Optical isolation 10 WIEGAND0 Output WIEGAND port 11 485B Bidirection RS485 12 GPIO7 Output Optical isolation 13 CANH Bidirection CAN port 14 CANL Bidirection CAN port 15 GND Environment requirement S N Item Parameters Unit Remark 1 Working temperature 20 70 2 St...

Page 7: ...rver host computer demo software as the TCP client side Notice RJ45 connecting only for HYR830 reader Support RS232 connecting baud rate 115200 1 bit for start 1 bit for stop 8 bits for data 1 Language Two optional languages are supported Simply Chinese English Open the DEMO software as picture 1 click red marked area could choose language Picture 1 Opening interface 2 Connection Demo software sup...

Page 8: ...h diff of port to 192 168 1 Picture 2 utomatically Picture 3 A th a prefix o correct COM 192 168 1 10 such as 192 t Ping operati fferent prefix 10 type NE 2 Ethernet po display usab Automatic ide of COM w M number a If connectin 168 1 100 B ion If connecting ET192 168 1 ort connection ble COM por entify serial p which user do and then it sh ng in Ethernet efore connec g with RJ45 10 as below n rts...

Page 9: ...ingle answer method of reading Each inventory will result an acknowledgement frame In each single inventory only one tag s EPC data could be gotten Single inventory mode supports to inventory tag function at any length EPC code At workspace area it could display EPC code Inventory times RSSI for each tag as below picture ...

Page 10: ...e inventory mode Inventory times are non limited At information area it will display Inventory speed time and tag numbers Click off line clean it will launch the function If a tag is not read in 4 seconds the marked color of the tag will turn grey if over 8 seconds the tag will be cleared from workspace ...

Page 11: ...ture is for TX power setting Picture 7 RF output power setting The TX power range is 5 30dBm with 1dBm stepping up Set the picked power and then get for checking the result Choose save the setting will be kept after power off 6 Region setting Region setting is in basic settings section as below picture Picture 8 Region setting ...

Page 12: ...ints of the frequencies Fixed frequency setting fill in the frequency at the blank then click add then click set if successful it will notice Click get can check out the set value Self defining frequency hopping setting input one frequency point click add then input another click add Repeat till you add all frequency points then click set You can click get to check if setting successfully 8 Versio...

Page 13: ... in basic settings as below picture Picture 12 Recommended link setting Recommended Link Settings DSB_ASK FM0 40KHz PR_ASK Miller 4 250KHz PR_ASK Miller 4 300KHz DSB_ASK FM0 400KHz Default Link setting is PR_ASK Miller 4 250KHz Choose save the setting will be kept after power off 11 Antenna setting Antenna setting is in Basic Setting as below picture Picture 13 Antenna setting ANT2 ANT3 ANT4 are n...

Page 14: ...orking and interval time setting The setting is for each antenna working time and interval time during multiple inventory Before the setting you should choose the antenna number For instance if want to set ANT1 of working time 300ms ANT2 of working time 350ms ANT3 of working time 300ms ANT4 of working time 500ms and waiting 1000ms for once reading cycle see following steps a Click ANT1 ANT2 ANT3 A...

Page 15: ...t low level the IO ports are not picked 16 CW setting CW setting is in advanced settings as below picture Picture 18 CW setting Click ON to open single carrier wave transmit OFF is to close single carrier wave transmit Test CW is for testing please ignore it 17 RX ADC info RX ADC information is displayed in advanced settings as below picture Picture 19 RX ADC information RX ADC is very important f...

Page 16: ...ry timeout setting Picture 21 Single inventory timeout setting This function is only for single inventory If single read is unsuccessful after the overtime the reader will report the result If the reading is successful during the overtime the response will be appeared immediately 20 Select and Query Setting In Advanced Settings section below is the picture for Select and Query parameter setting Pi...

Page 17: ...n of the tag even the tag has been locked but have to access the password for writing TID is only for read can t for write Read Write setting is usually operated with filter operation which means you can read write those picked EPC tag and avoid to reading writing un picked tags Steps are as following Find the tag on workspace which you want to reading and writing double click the EPC number enter...

Page 18: ...ns you can kill the picked EPC tags and avoid killing un picked tags Steps are as following Find the tag on Workspace which you want to kill double click the EPC number enter tag operate interface then you can operate 24 FastID Function Picture26 FastID Operation screen Click FastID then you can start FastID function When you open FastID on single inventory and continuous inventory the EPC and TID...

Page 19: ...RFID Reader 25 TagFocus Function Picture27 TagFocus Operation screen Click TagFocus then you can start TagFocus function ...

Page 20: ...y cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or r...