WR-G35DDCi Multichannel Coherent Application Guide for Extended topology configuration (ETC)
12
2.2.11 Digital synchronization cable for the Coherent clock
generator board
Similar to the digital synchronization cables described in the previous Section, this cable is
unused in the ETC configuration, therefore do not install this cable. However, this cable
should be kept safely, in case the Clock Kit is required to operate in standard (non-ETC)
coherent receiver operation in the future.
Picture 2-8:
Digital synchronization cable for the Coherent clock generator board,
unused in the ETC configuration (see text)
2.2.12 Frequency reference SMA interconnect cable
The frequency reference SMA interconnect cable is used to interconnect the internal
reference output REF OUT of the Coherent clock generator board to the frequency reference
input REF IN of the same board, after it is installed into a PC. If an external frequency
reference is used, this cable is not needed and should be kept safely, in case the internal
reference operation is required in the future.
For installation of the cable please refer to chapter 3 of this document.
Picture 2-9:
SMA interconnect cable for the frequency reference