Collector acceptable = Pass Collector Inspection
Collector acceptable, but
fl
at gasket = Fail and Repair Promptly
Collector not acceptable = Fail and Remove Fryer from Use until Repaired
Gasket is frayed or torn = Fail and Remove Fryer from Use until Repaired
6.
Fryer Pot Inspection
- Inspect inside fryer pot for any cracks or holes.
Pot acceptable = Pass Fryer Pot Inspection
Pot not acceptable = Fail and Remove Fryer from Use until Repaired
Step 3 - Operation Component Inspection
1.
Drain Valve Inspection
- Inspect Drain Valve (Fig. M) for shortening leaks or missing components.
If leaking exists, determine if leaking is internally on the drain itself, externally from fryer mounting,
or unknown.
Drain Valve acceptable = Pass Drain Valve Inspection
Drain Valve Leaking Internally = Fail and Repair Promptly
Drain Valve Leaking from Pot or Unknown = Fail and Remove Fryer from Use until Repaired
2.
High Limit Thermostat Inspection
- Inspect high limit thermostat (Fig. N) to ensure it is present,
securely mounted to fryer wall, and in the clamp.
Fig. M - Drain Valve
Fig. N - High Limit Thermostat
Clamp
Hi Limit Probe