101019
OPERATIONS MANUAL PPM-LX800-G
38
File Download
Assuming the same connection settings as those referenced above, to send a file called APP.EXE
from the PPM-LX800-G to a WINCOM client PC, use the following command:
scopy com2 -sq app.exe -b115200
If no file path is provided, the file must exist in the current directory on the
PPM-LX800-G. Otherwise, a path must be specified.
Once SCOPY has been started on the PPM-LX800-G in send mode, WINCOM must be told to
receive the file. To start the download, press <ALT><PgDn> on the WINCOM client keyboard.
WINCOM will respond with:
File to Download :
Type the name of the file to be downloaded and press
<ENTER>.