F.3.2. Control of the electronic brake for electrodynamics stopping of engine
The machine has electronic brake for electrodynamics stopping of engine.
The time for full stopping of the tool turning must not surpass 10 seconds from switching of the en-
gine.
This stopping time must be controlled every month.
If it is more than 10 seconds electrician must check up the brake.
The frequency of the switching on of this brake must be most 10 for on hour.
Removal from operation, storage – disassembly (rejection) of the machine
Switch off all electrical equipment during removal of the machine.
Provided the machine would not be use for some time, after switching off of all electrical equipment,
clean it thoroughly and process the operation board, the shaft of the circular disk and the other unpainted
parts by roof-protection product.
You should not store the machine in damp places and must protect it from environmental effects.
The machine is produced by non-toxic and safe materials. Upon rejection divide the metal and plastic
parts and smash them afterwards.
Emergency situations /states/
Switch off the electric supply immediately in case of flood of the operation area.
Before re-operation of the machine, it must be checked by trained authorized technician.
Switch off the electric supply in case of fire and use fire extinguishers.
Direct the jet to the base of the flame.
Before re-operation of the machine, it must be checked by trained authorized technician.
The operation area around the machine (please refer to Section C.1.) must always be unoccupied.
You must not operate the machine in environment presenting danger of explosion.
F.4. TROUBLE-SHOOTING
WARNING
Before starting any repair works switch off the electric supply of the machine.
The machine has been tested in the production plant and you can freely operate it.
The incorrect and out of function use of the machine may result in damages.
Fault:
The machine does not start.
Reason:
Repair:
- No voltage in the electric mains.
Check whether the three phases are under ten-
sion. Check all options: L1-L2, L1-L3, L3-L2
fig. 29.
If there is not tension at all the 3 cases, it
means that there is no voltage in the electric
mains.
-If, for instance, there is not voltage between L1-
L2 and L3-L2, the reasons are:
-lack of one phase in the supply device
-damaged fuse in the distribution box of the sup-
ply device
fig. 29
-loosen cable L2