15
Procedures
Required material:
Kit heating element 4.9KW with fuse
Item no.
Kit heating element 6.5KW with fuse
item no. 30 000 124 (Japan, Australia)
Tool:
no special tool required
Note for UC-S
The following manual applies for the
UC-M; -L; -XL. In models of the UC-S
Series the boiler is located behind the rear
panel and can be accessed easily
Observe the safety notes on page 7
UC-M, UC-L, UC-XL
Remove the front panel
Pull the suction pipes out of the chemical containers
Remove the right stiffener wall
Completely drain boiler
Disconnect the main power cable of the boiler heating element
Unscrew 3 hexagonal nuts
Pull out the boiler heating element
If necessary, clean boiler on the inside
Replace the existing o-ring seal by a new one
Install the new boiler heating element
Connect the main power cable
Wires 1-3 connected to the gate at 2, 4, 6
Wires 4-6 connected to the clips X1-4, -5, -6
green-yellow wire connected to a grounding clip
Install the stiffener wall
Put the suction pipes into the chemical containers
Install the front panel
Carry out a function test
Ventilate the dosing devices
Carry out a safety test according to VDE 0701
Summary of Contents for UC-L
Page 1: ...Winterhalter Undercounter Dishwashers UC Series Repair manual ...
Page 10: ...8 Exchange collector ...
Page 12: ...10 Exchange collector continuation ...
Page 14: ...12 Exchange collector continuation ...
Page 16: ...14 Exchange boiler heating element ...
Page 18: ...16 Exchange boiler ...
Page 22: ...20 Exchange tank heating element ...
Page 24: ...22 Exchange pump head dosing device Fluidos ...
Page 26: ...24 Exchange dosing device Fluidos ...
Page 28: ...26 Exchange integrated water softener ...
Page 30: ...28 Exchange integrated water softener continuation ...
Page 32: ...30 Exchange heat exchanger radial fan ...
Page 34: ...32 Exchange heat exchanger radial fan continuation ...
Page 46: ...44 ...
Page 47: ......