5.2.2
Lubricating quill
The lubricating quills spray oil onto the cylinder liner wall. The lubricating quills are installed on the
circumference of the cylinder liner.
The cylinder lubricating pump supplies a specified quantity of cylinder oil at high pressure through
the cylinder oil inlet (006,
) into the lubricating quills. The non-return valve (009) opens
and the cylinder oil flows out of the nozzle tip (003) and the lubricating point (004) as a spray.
Some of the cylinder oil flows into the grooves of the cylinder liner wall. The non-return valve (009)
prevents the exhaust gas to flow back into the oil pipe.
Fig 5-8
Lubricating quill (generic)
001
002
003
004
008
007
006
009
005
Legend
001
Piston
006
Cylinder oil inlet
002
Piston ring
007
Holder
003
Nozzle tip
008
Cylinder liner
004
Lubricating point in cylinder liner
009
Non-return valve
005
Compression spring
X52
AA00-2138-00AAA-043A-A
Operation Manual
Lubricating quill
Winterthur Gas & Diesel Ltd.
- 126 -
Issue 002 2018-11