5.4.4.1
Local control panel
NOTE:
If a fault occurs in the remote control, which prevents engine control from the control
room, you can operate the engine from the local control panel.
The local control panel (001) has the electronic components that follow:
•
Local display unit (LDU-20)
There are two LDU-20 (002,
). One LDU-20 is installed in the local control
panel (001). The other LDU-20 is installed in the engine control room. The two LDU-20
operate independently from the remote control system. For more data about the LDU-20,
refer to
6.3 Local display unit (LDU-20) - general
•
ME tachometer
The ME tachometer (003) shows the engine speed in the ahead or astern directions.
•
Emergency stop button
NOTE:
Not all local control panels have an emergency stop button installed.
When you operate the emergency stop button (not shown), the engine stops immediately.
The fuel pressure control valve (PCV) releases the pressure in the fuel rail. At the same
time, the fuel pump supply decreases to 0 (zero).
○
For data about the PCV, refer to
○
For data about engine stop, refer to
•
Telegraph receiver
The telegraph system is part of the propulsion control system, refer to
.
X52
AA00-4618-00AAA-043A-A
Operation Manual
Local maneuvering stand
Winterthur Gas & Diesel Ltd.
- 159 -
Issue 002 2018-11