PROCEDURE
1
Change over to the clean filter chamber.
2
Drain the clogged filter chamber.
3
Remove the cover of the clogged filter chamber.
4
Remove the filter element from the filter chamber.
5
Clean the filter chamber.
6
Clean the filter element or take a new filter element.
7
Install the new filter element into the filter chamber.
8
Install the cover on the filter chamber.
9
Make sure that the cleaned filter chamber has no leaks.
CLOSE UP
•
None
X52
AA00-7200-00AAA-200A-A
Operation Manual
Replace the filter element of the duplex filter
Winterthur Gas & Diesel Ltd.
- 337 -
Issue 002 2018-11