Tab 11-12 Exhaust gas system (XX37NN)
Description
Usual oper-
ation (value
or range)
Safeguard setting
Medium / physical value / location
Signal number Func-
tion
Le-
vel
Trigger
value
De-
lay
Exhaust pipe / manifold
Exhaust gas / temperature [°C] / outlet each
cylinder
-
TE3701-nnA
ALM
H
≥
515
0
ALM
D
≥
50
0
SLD
H
≥
530
60
SLD
D
≥
70
60
Exhaust gas / temperature [°C] / inlet each
turbocharger
-
TE3721-nnA
ALM
H
≥
515
0
SLD
H
≥
530
60
Exhaust gas / temperature [°C] / outlet each
turbocharger
-
TE3731-nnA
ALM
H
≥
480
0
SLD
H
≥
500
60
X52
AA00-0000-00AAA-033B-A
Operation Manual
List of usual values and safeguard settings
Winterthur Gas & Diesel Ltd.
- 431 -
Issue 002 2018-11