INSTRUCTION MANUAL 

Modular air curtain 

ACM 

 

 

 

 

 

THIS DOCUMENT MUST BE READ BEFORE STARTING THE INSTALLATION.  

INSTRUCT USER AND LEAVE THIS DOCUMENT WITH APPLIANCE FOR 

REFERENCE  

 

 

 

 

 

 

 

 

 

 

 

BI_ACM_GB_02

Summary of Contents for ACM

Page 1: ...1 INSTRUCTION MANUAL Modular air curtain ACM THIS DOCUMENT MUST BE READ BEFORE STARTING THE INSTALLATION INSTRUCT USER AND LEAVE THIS DOCUMENT WITH APPLIANCE FOR REFERENCE BI_ACM_GB_02 ...

Page 2: ...r power plug 6 4 2 Connection options 6 4 2 1 Connection without speed control 6 4 2 2 Connection with door switch 6 4 2 3 Connection with speed control 6 5 SETTING OPERATION AND MAINTENANCE 7 5 1 Operation 7 5 2 Maintenance 8 6 Assembly and electrical instructions 9 6 1 Assembly GVACM GA8700 9 6 2 Electrical connections with and without speed controller 10 6 3 Electrical connections door switch w...

Page 3: ...n functions as an invisible door segregation and has insulation properties this can reduce energy losses up to 80 with an open door The air curtain can be used with chilled or heated spaces In most circumstances an air curtain is used to minimise heat losses with an open door it could also be used as a segregation between a non or limited heated space and warmer heated space For example between a ...

Page 4: ... 1 5 1 5 Max suspension height m 4 5 4 5 4 5 4 5 4 5 4 5 4 5 4 5 4 5 4 5 Air output cold m h 1900 3800 5700 7600 9500 11400 13300 15200 17100 19000 Voltage 50Hz V 230 230 230 230 230 230 230 230 230 230 Protection rating IP IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 Accumulated power consumption A 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 10 0 Sound level 5m dBA 64 67 69 70 71 72 73 73 73 74 Weig...

Page 5: ...ough overlay 3 3 Positioning Make sure the air curtain has undisrupted flow of intake air and blown air there should be a minimum distance of 0 5meter between ceiling or overhead door Horizontal mounting is preferred above vertical mounting because that way the air curtain will also serve as a recirculation fan and the air stream will be warmer than on floor level The side of the air stream should...

Page 6: ... The installer should connect a 3 wire mains cable and a power plug to it 4 2 Connection options 4 2 1 Connection without speed control With the interference of an isolation switch or power plug the air curtain can be connected to the mains If the connection is made the fans will run continually at full speed See chapter 6 2 4 2 2 Connection with door switch The air curtain can be activated as the...

Page 7: ...y turbulence and excessive sound The ideal flow profile is depicted in the illustration beneath one can roughly check this by feeling with the hands or tuft testing with a string of paper to visualise the airflow profile But off course an anemometer would be best If there is a strong wind load on the door opening one can turn up the airspeed The air curtain isolates the interior space thus it can ...

Page 8: ... 3 2 5 3 5 4 3 25 4 25 5 4 4 5 Step 5 2 Maintenance In spaces with heavy dust it might be necessary to clean the fan guard with compressed air once a year If the fan guard is covered with severe dust the fan will have diminished suction capabilities ...

Page 9: ...Assembly GVACM GA8700 The ACM modules and assembly set have to be assembled as depicted with use of included parkers key size 7 Article no 1 GVACM 2 GA8700 Spare parts IX4200 Fan Ø350 IW5903 Internal wiring IW5904 Power plug connector IW5405 Appliance plug ...

Page 10: ...n Air Curtain Module Luchtgordijn met optionele standen regelaar Circulation unit with optional speed switch Te maken aansluitingen Connections to be made Motor M Motor M Motor M Motor M Motor M Motor M L 230V AC N L1 L1 N N Fan 5 standen schakelaar 5 speed switch Te maken aansluitingen Connections to be made 6 2 Electrical connections with and without speed controller ...

Page 11: ...itch and door switch Te maken aansluitingen Connections to be made Motor M Motor M Motor M Deurcontact Door switch L1 N L1 N Deurcontact relais box Door switch relay box 5 standen schakelaar 5 speed switch 5 Stufenregler Te maken aansluitingen Connections to be made L 230V AC N L1 L1 N N Fan Te maken aansluitingen Connections to be made Motor M Motor M Motor M Deurcontact Door switch L1 N L1 N Deu...

Page 12: ...12 1 4 0 0 4 0 300mm 7 Attachment 7 1 Installation vertical mounting set Article no 1 GVACM 4 GA8585 0 Not Included ...

Page 13: ...13 260 307 5 567 5 12 5 20 600 7 1 Installation vertical mounting set Max 10 modules ...