7
INSTALLATION MANUAL
AIR HEATER TYPE DXC
3.2.3
Butane / LPG
Specification
Unit
Butane / LPG G30 (B/P)
Nominal supply pressure
mbar
30-50
Supply pressure (min. - max.)
mbar
25-50
Gas category
-
II
2
H
3
P B/P
NL: II
2
EK
3
B/P
DE: II
2
ELL
3
B/P
BE: I
3
B/P
FR: II
2
Er
3
B/P
PL: II
2
ELwLs
3
B/P
Class
-
B22, C12, C32
Specification
Unit
DXC60
DXC80
DXC100
Gas consumption
m
3
/h
3.9
5.0
6.5
Burner injectors
n x Ømm
5x 2.3
6x 2.3
8x 2.3
Burner pressure high
mbar
13.5
15.0
14.5
Burner pressure low
mbar
6.0
6.0
6.5
CO
2
High (indication)
%
9.2
9.2
9.2
3.3 Dimensions
The dimensions of this air heater can be found in figure 1.
B
108
0
1125
A
2100
T1
T2
T3
T5
T4
T5
T4
T3
Figure 1 - Dimensions of the DXC
Dimension
Unit
DXC60-80
DXC100
A
mm
575
650
B
mm
740
815
T1
-
Electrical supply
T2
-
Function switch
T3
-
Flue discharge
T4
-
Flue supply
T5
-
Gas supply (¾")