background image

P A G E

 | 

2

 

 

 

 
 

 

Wintex Agro, Vilhelmsborgvej 8C, DK-7700 Thisted 

+45 97990800, contact@wintexagro.com, www.wintexagro.com

 

 

 
 

 
 
Manufactured by:

 

WINTEX AGRO 

 

Vilhelmsborgvej 8C 

 

DK-7700 Thisted 

 

Type designation:

 

WINTEX 2000 

 

Voltage:

  

12 volt DC 

 

Year of production:

 

2019 

 

 
 
 
 

 

 

 
 

 
 
 

 
 
 

 
 
 
 
 

 
 

FOR YOUR SAFETY 

 

Before starting

 the WINTEX 2000 please make sure that nobody is present within a range of 10 meters. 

 

When inspecting the WINTEX 2000, you must always activate the emergency stop, and the ATV must be turned off. 

 

Every time

 you start the WINTEX 2000, you must 

test the emergency stop

. If the emergency stop does not turnoff the soil sampler, you 

must not use it. 
 
The WINTEX 2000 has sliding and rotating parts. Keep your limbs away from the soil sampler unless it is turned off, and stay away 
from the foot / the base of the soil sampler. 

 
 

 

Summary of Contents for 2000

Page 1: ...8C DK 7700 Thisted 45 97990800 contact wintexagro com www wintexagro com INSTRUCTION MANUAL WINTEX 2000 0 60 cm For all soils Fully automatic Optimum speed Minimum maintenance Robust reliable Hydraulic hammer Two samples in one step 201905 ...

Page 2: ...0 please make sure that nobody is present within a range of 10 meters When inspecting the WINTEX 2000 you must always activate the emergency stop and the ATV must be turned off Every time you start the WINTEX 2000 you must test the emergency stop If the emergency stop does not turnoff the soil sampler you must not use it The WINTEX 2000 has sliding and rotating parts Keep your limbs away from the ...

Page 3: ...op must always be activated at long stops or the battery might be discharged 2 SELECTION OF PROGRAM Program 1 takes a soil sample from 0 60 cm The depth can be adjusted Program 2 takes soil samples from two different layers from 0 30 cm and from 30 60 cm The depth can be adjusted The soil sampler is adjusted to standard rotation extra rotation off It is possible to add an extra rotation extra rota...

Page 4: ...e process will stop immediately When reactivating the foot switch and the brake handle at the same time the probe will go back into start position The soil will be discarded and not filled into the soil boxes If the soil sampler is delivered with a remote control the process will be interrupted by activating the stop switch of the remote control instead 5 REPLACEMENT OF O RING SCRAPER AND PROBE Re...

Page 5: ...he probe is removed it is possible to replace the O ring REPLACEMENT OF SCRAPER At first force the spring roll pin out Then replace the scraper and replace the old spring roll pin with a new one 6 ADJUSTMENT OF CHAIN FOR ROTATION Loosen the four screws with a 4 mm hex key Then adjust the chain for rotation by turning the insex bolt clockwise to tighten the chain counter clockwise to loosen the cha...

Page 6: ... down when pulling the valve The probe goes up when pushing the valve Rotation Screw counter clockwise to activate the rotation process Then press the main valve Important Re set the button into start position after use Do always activate the main valve by pressing it down when activating the other functions 9 ADJUSTING THE HYDRAULICS ADJUSTING THE MAIN PRESSURE Start the motor with max r p m Pres...

Page 7: ...ure The pressure is from the factory pre set at a proper pressure Yet it might be necessary to adjust it a bit so that the soil sampler stands firmly on the ground ADJUSTING THE ROTATION SPEED OF THE PROBE Press the button down and turn it counter clockwise The button will come up Start the motor with max r p m Press the main valve and the probe will rotate Loosen the lock nut The rotation speed i...

Page 8: ...ead the pressure on this manometer which only is for reading the pressure of the probe 10 ADJUSTING AND MOUNTING THE SENSORS The upper sensor plate determines if the probe is in top position The sensor plate in the middle determines where the soil sample will be divided The lower sensor plate determines the depth in which the soil sample will be taken The gap between both sensors and the sensor pl...

Page 9: ...t the sensor and the sensor plug correctly by being aware of the notch 11 PROTECTION AGAINST OVERHEATING If the oil temperature exceeds 70O C the electricity box will be temporarily disconnected and the red indicator light will be on Wait until the temperature of the oil has lowered In extremely hot areas or if the oil temperature would become a problem shift to another oil type ...

Page 10: ...P A G E 10 Wintex Agro Vilhelmsborgvej 8C DK 7700 Thisted 45 97990800 contact wintexagro com www wintexagro com 12 ELECTRICITY BOX Connection of wires in the electricity box ...

Page 11: ...P A G E 11 Wintex Agro Vilhelmsborgvej 8C DK 7700 Thisted 45 97990800 contact wintexagro com www wintexagro com 13 HYDRAULICS ...

Page 12: ...the hydraulic oil and refill with oil if necessary Check the hydraulics for leaks Clean the oil tank Clean the oil cooler Check weekly and exchange adjust if necessary 50101038 Guiding rolls 16101022 Guiding pipe 16101002 Rotary sensor plate 50101044 Slide bearing 50101045 Gearwheel for rotation 30 teeth 50101046 Gearwheel for rotation 12 teeth Check daily and exchange if necessary 50101004 O ring...

Page 13: ...s Lubricate the probe 2 Replace the accumulator with a new one 3 Replace the hydraulic oil pump with a new one 4 Replace the hydraulic oil filter The probe must be able to move freely for 15 20 mm The probe does not rotate properly 1 The push button on the rotation valve is activated 2 The sensors for rotation are not adjusted correctly 1 Deactivate the push button by pressing and turning it clock...

Page 14: ... piston is stuck in the cylinder 1 Switch hose P and hose T 2 Polish or replace the components The hammer works irregularly 1 There are impurities in the hydraulic oil 2 The oil level in the power source is too low 1 Replace the oil and the oil filter 2 Add hydraulic oil The hammer performs badly 1 There is an internal leak 2 The oil flow from the power source towards the hammer is incorrect 3 The...

Page 15: ...n the hole the accumulator to check if the accumulator is pressurized If the diaphragm can be pushed a lot the accumulator must be charged with Nitrogen or the diaphragm is defective In case of a defective diaphragm the accumulator must be replaced Loosen the charging screw with a 6 mm hex key If the accumulator is in order you can hear a whistling sound of Nitrogen In this case merely recharge th...

Page 16: ...ntact wintexagro com www wintexagro com 19 CHANGING OIL AND OIL FILTER Plug the filling hole with a solid plug Remove both hoses Unbolt the engine and the tank Remember the bolt under the tank Slide the engine and the tank out under the cooler bracket and unbolt the engine ...

Page 17: ...ump Replace the filter with a new one Clean the tank thoroughly Then remount pump tank and engine Interval Type Qty Adjustment Check daily Wintex 2000 Filler cap 5000 1 year Wintex Hydraulic oil 5000 1 year EZ 46 7 5 4 5 X Honda motor Valves 300 1 year X Air filter 100 1 year Spark plug 100 6 month BPR6ES 1 Motor oil 100 6 month 5w 30 10w 30 API SJ or better 0 6 X ...

Reviews:

Related manuals for 2000