P A G E
|
3
Wintex Agro, Vilhelmsborgvej 8C, DK-7700 Thisted
+45 97990800, contact@wintexagro.com, www.wintexagro.com
1.
STARTING THE WINTEX 2000
Start the vehicle, and deactivate the emergency stop. The red button must be up.
Activate the foot switch and the brake on the handle bar, and shortly push the button at your right
hand. Foot switch and brake lever must be activated during the entire process. If one of these
switches is released, the process will stop.
If the soil sampler is delivered with a remote control, activate the dead-
man’s vigilance system
instead of the foot switch.
Note: The emergency stop must always be activated at long stops, or the battery might be
discharged.
2.
SELECTION OF PROGRAM
Program 1 takes a soil sample from 0-60 cm. The depth can be adjusted.
Program 2 takes soil samples from two different layers, from 0-30 cm and from 30-60 cm. The depth
can be adjusted.
The soil sampler is adjusted to standard rotation (= extra rotation “off”).
It is possible to add an extra rotation
(= extra
rotation “on”).
3.
ADJUSTING THE DEPTH
The lower sensor plate defines the depth in program 1 and in program 2. Loosen the screws, and
move the sensor plate up or down to the desired depth.
The upper sensor plate defines where the soil sample in program 2 will be divided. The depth can be
adjusted from 0-30 cm. Loosen the screws, and move the sensor plate to the depth in which the soil
sample shall be divided.