P A G E
|
8
Wintex Agro, Vilhelmsborgvej 8C, DK-7700 Thisted
+45 97990800, contact@wintexagro.com, www.wintexagro.com
ADJUSTING THE PRESSURE OF THE PROBE
Loosen the lock nut. Adjust with a 6 mm hex key. Pressure will rise when turning to the right.
Lower the pressure by turning to the left.
Depending on the vehicle’s weight and the kind of soil, the pressure must be between 10 and 30 bar.
Read the pressure on this manometer, which only is for reading the pressure of the probe.
10.
ADJUSTING AND MOUNTING THE SENSORS
The upper sensor plate determines if the probe is in top position.
The sensor plate in the middle determines where the soil sample will be divided..
The lower sensor plate determines the depth in which the soil sample will be taken.
The gap between both sensors and the sensor plates must be 2-3 mm. Make sure that the gap of both
sensors towards the sensor plates is exactly the same. It is recommended to adjust the sensors in relation
to the lower sensor plate.