SmartPAC PRO User Manual
Appendix C – Reporting Downtime and Scrap to SFC
265
Field
Settings
DIALOG SCREEN
MODE
Indicates whether downtime reasons are created on the screens
accessible from the SET SPECIAL NAMES and SET CANNED NAMES
menu items (see below) or in ShopFloorConnect Administrator. There are
two settings:
16 / 16
Downtime reasons are created in SmartPAC
32 CUSTOM Downtime reasons are created in SFC
When the “16 / 16” setting is selected, you can create only 16 custom
downtime reasons, and only those reasons can be included in the
Downtime by Reason Report. The “32 CUSTOM” setting enables you to
create up to 32 custom reasons, all of which can appear in the Downtime
by Reason Report. When the “32 CUSTOM” setting is selected, the SET
SPECIAL NAMES and SET CANNED NAMES items do not display.
UNPLANNED RESET
STROKES
PLANNED RESET
STROKES
CHANGEOVER RESET
STROKES
Specifies the number of strokes that must occur after the press is restarted
following a period of Unplanned Downtime, Planned Downtime, or
Changeover Time before SFC begins documenting the machine state as
“Running Time.” This setting prevents additional press time from being
attributed to a downtime reason when the operator forgets to select the
“BACK ON LINE” item from the Dialog Menu. The number of strokes you
specify should be the maximum number of press cycles that are likely to
be needed to return the press to production. Valid entries: 1-9999.
Suggested settings:
Set the Unplanned Reset Strokes counter to two strokes more than the
maximum number of strokes required to fill an empty die. This setting
should give the operator sufficient time to complete a response to the
downtime cause (such as Coil Change) that requires the longest time to
address.
Set the Planned Reset Strokes counter to the lowest number of strokes
required to return the press to production following a lunch or other
break.
Set the Changeover Reset Strokes counter to the maximum number of
strokes required to complete a die setup.
SINGLE STROKE
MODE
This setting, which is used for hand-fed applications when the press is
being run in Single-stroke mode, indicates whether SFC counts press
cycles (or parts made) within the period specified in the IDLE TIMER field
(see next entry) to determine whether the press is “running.” When this
field is set to “ENABLED,” SFC only documents the press as “Idle” when
no cycles occur (i.e., no parts are made) during an Idle Timer period.
There are two settings:
ENABLED
Single-stroke Mode enabled
DISABLED
Single-stroke Mode disabled
Summary of Contents for SmartPAC PRO
Page 1: ......
Page 2: ......
Page 4: ......
Page 6: ......
Page 20: ......
Page 22: ......
Page 24: ......
Page 42: ...1143100 SmartPAC PRO User Manual 42 Chapter 1 Introduction to SmartPAC PRO ...
Page 142: ...1143100 SmartPAC PRO User Manual 142 Chapter 4 SmartPAC PRO Program Mode ...
Page 200: ...1143100 SmartPAC PRO User Manual 200 Chapter 6 Using DiProPAC Die Protection Optional ...
Page 222: ...1143100 SmartPAC PRO User Manual 222 Chapter 7 ProCamPAC Instructions ...
Page 254: ...1143100 SmartPAC PRO User Manual Appendix C SmartView Remote Viewing and E mail Setup 254 ...
Page 280: ...SmartPAC PRO User Manual 1143100 280 Appendix C Reporting Downtime and Scrap to SFC ...
Page 290: ...SmartPAC PRO User Manual 1143100 290 Index Y yellow fault 232 yellow sensor 169 ...
Page 292: ......
Page 294: ......
Page 296: ......
Page 298: ......
Page 300: ......
Page 301: ......
Page 302: ......
Page 303: ......
Page 304: ......
Page 305: ......
Page 306: ......
Page 307: ......
Page 308: ......
Page 309: ......
Page 310: ......
Page 311: ......
Page 312: ......
Page 313: ......
Page 314: ......
Page 315: ......
Page 316: ......
Page 317: ......
Page 318: ......