Chapter 6 – Using DiProPAC Die Protection (Optional)
Figure 6-11. Sensor Program Screen, Auto Reset = OFF
Bypass Angle (Static Sensors)
Sometimes it is useful to use a Bypass Angle to prevent nuisance stops, for example, when using a
proximity sensor to monitor material buckle. When the material is near the sensor (not buckled), the
sensor is ON, and it is set up as a Red sensor. However, sometimes when the die opens, the material
jumps off the sensor enough to cause a nuisance stop.
In such cases, you can program the optional Bypass Angle for Yellow and Red sensors. During the
bypass, SmartPAC PRO ignores the sensor, so any fault during that window will not cause a nuisance
stop. During the rest of the stroke, SmartPAC PRO monitors the sensor normally.
To set the Bypass Angle, follow these steps:
1.
In the Sensor Program Screen, Figure 6-11, press the ADD button for BYPASS ANGLE. The
Bypass Angle screen appears.
2.
Use one of these ways to set the bypass angle (the portion of the stroke when the sensor is
ignored):
•
the plus (+) and minus (–) buttons on the screen
•
SET ON ANGLE and SET OFF ANGLE buttons. Press SET ON ANGLE and key in the ON
angle on the keypad that appears. Press Enter. Press SET OFF ANGLE and key in the OFF
angle on the keypad that appears. Press Enter.
Summary of Contents for SmartPAC PRO
Page 1: ......
Page 2: ......
Page 4: ......
Page 6: ......
Page 20: ......
Page 22: ......
Page 24: ......
Page 42: ...1143100 SmartPAC PRO User Manual 42 Chapter 1 Introduction to SmartPAC PRO ...
Page 142: ...1143100 SmartPAC PRO User Manual 142 Chapter 4 SmartPAC PRO Program Mode ...
Page 200: ...1143100 SmartPAC PRO User Manual 200 Chapter 6 Using DiProPAC Die Protection Optional ...
Page 222: ...1143100 SmartPAC PRO User Manual 222 Chapter 7 ProCamPAC Instructions ...
Page 254: ...1143100 SmartPAC PRO User Manual Appendix C SmartView Remote Viewing and E mail Setup 254 ...
Page 280: ...SmartPAC PRO User Manual 1143100 280 Appendix C Reporting Downtime and Scrap to SFC ...
Page 290: ...SmartPAC PRO User Manual 1143100 290 Index Y yellow fault 232 yellow sensor 169 ...
Page 292: ......
Page 294: ......
Page 296: ......
Page 298: ......
Page 300: ......
Page 301: ......
Page 302: ......
Page 303: ......
Page 304: ......
Page 305: ......
Page 306: ......
Page 307: ......
Page 308: ......
Page 309: ......
Page 310: ......
Page 311: ......
Page 312: ......
Page 313: ......
Page 314: ......
Page 315: ......
Page 316: ......
Page 317: ......
Page 318: ......