1143100
SmartPAC PRO User Manual
188
Chapter 6 – Using DiProPAC Die Protection (Optional)
Setting the Ready Signal for a Green Sensor
After you select the stop type for a Green, Green Quick Check, Green Constant, or Green Flex sensor,
the Ready Signal Programming screen displays, Figure 6-32.
The Ready signal is the timing window during which the sensor must actuate to prevent SmartPAC
PRO from sending a stop signal to the press. The example below shows the Ready signal On at 260
and Off at 20
.
Figure 6-32. Ready Signal Programming Screen
To set the Ready signal, use either the plus and minus buttons or the buttons labelled SET ANGLE
ON and SET ANGLE OFF, as follows:
1.
Set the Ready On angle:
•
Press the plus and minus (+/–) buttons to adjust on angle shown inside the clock display
circle to the desired value.
OR
•
Press SET ON ANGLE. A numeric entry window opens. Key in the desired ON angle and
press Enter.
2.
Set the Ready OFF angle in a similar way.
3.
When you have finished setting the Ready On and Ready Off angles, press Back. The Sensor
Program screen displays, showing the sensor settings you made, Figure 6-27, page 183.
4.
If you want to change any settings, refer to
Viewing and Changing Sensor Settings
Otherwise, press Exit to return to the Die Protection Sensor Menu. The highlight bar
automatically scrolls down to the next sensor displayed on the menu.
Summary of Contents for SmartPAC PRO
Page 1: ......
Page 2: ......
Page 4: ......
Page 6: ......
Page 20: ......
Page 22: ......
Page 24: ......
Page 42: ...1143100 SmartPAC PRO User Manual 42 Chapter 1 Introduction to SmartPAC PRO ...
Page 142: ...1143100 SmartPAC PRO User Manual 142 Chapter 4 SmartPAC PRO Program Mode ...
Page 200: ...1143100 SmartPAC PRO User Manual 200 Chapter 6 Using DiProPAC Die Protection Optional ...
Page 222: ...1143100 SmartPAC PRO User Manual 222 Chapter 7 ProCamPAC Instructions ...
Page 254: ...1143100 SmartPAC PRO User Manual Appendix C SmartView Remote Viewing and E mail Setup 254 ...
Page 280: ...SmartPAC PRO User Manual 1143100 280 Appendix C Reporting Downtime and Scrap to SFC ...
Page 290: ...SmartPAC PRO User Manual 1143100 290 Index Y yellow fault 232 yellow sensor 169 ...
Page 292: ......
Page 294: ......
Page 296: ......
Page 298: ......
Page 300: ......
Page 301: ......
Page 302: ......
Page 303: ......
Page 304: ......
Page 305: ......
Page 306: ......
Page 307: ......
Page 308: ......
Page 309: ......
Page 310: ......
Page 311: ......
Page 312: ......
Page 313: ......
Page 314: ......
Page 315: ......
Page 316: ......
Page 317: ......
Page 318: ......