1143100
SmartPAC PRO User Manual
Appendix C – Reporting Downtime and Scrap to SFC
255
Appendix C Reporting Downtime and
Scrap to SFC
This appendix shows you how to report press downtime from your SmartPAC PRO control to
Wintriss’s ShopFloorConnect Asset Utilization Software (SFC). The appendix discusses the six
machine states to which SFC logs press time, explains the downtime reporting features of SmartPAC
PRO, shows you how to set up SmartPAC PRO to report downtime to SFC, and provides instructions
for reporting downtime.
The appendix also shows you how to use the scrap counter on the SmartPAC PRO Counters screen in
Run mode to report scrap to SFC and how to adjust the Good Parts count that is reported to SFC.
SmartPAC’s downtime- and scrap-reporting features are available if SFC firmware option is
installed.
Machine States to Which SFC Logs Press Time
SFC logs all elapsed time at each press to one of six categories called machine states. The sum of all
the times assigned to these machine states for an individual press is the number of hours in a
production day (e.g., 12 hours, 24 hours, etc.). SFC selects the machine state to which to log press
time on the basis of downtime reporting and other information it receives from SmartPAC PRO.
Machine states are differentiated as follows:
•
Running Time–Press is running and making parts
•
Idle Time–Press is stopped, no SmartPAC error has occurred, and the reason the press is
stopped has not been documented in SmartPAC PRO
•
Unplanned Downtime–Press is stopped due to a SmartPAC PRO error, or if the press is
stopped for another reason, that reason has been assigned to the Unplanned Downtime state in
SFC
•
Planned Downtime–Press is stopped, and the reason has been assigned to the Planned
Downtime state in SFC
•
Changeover Time–Press is stopped, and the reason has been assigned to the Changeover state
in SFC
•
Offline Time–Press is stopped because there is no power to the press or the network is down
All time during which the press is stopped for any reason other than a power interruption or network
failure is logged by SFC to Idle Time unless a downtime reason is reported from the SmartPAC PRO.
Idle Time is treated in ShopFloorConnect as downtime with no documented reason. Since corrective
action cannot be taken until a cause is identified, SmartPAC PRO has been designed to allow very
precise reporting of downtime to SFC and may be programmed to require the operator to select a
specific downtime reason each time the press enters an Idle state. When operator intervention is
required, periods of press inactivity are more likely to be assigned to a specific downtime reason than
to be logged as Idle Time.
Summary of Contents for SmartPAC PRO
Page 1: ......
Page 2: ......
Page 4: ......
Page 6: ......
Page 20: ......
Page 22: ......
Page 24: ......
Page 42: ...1143100 SmartPAC PRO User Manual 42 Chapter 1 Introduction to SmartPAC PRO ...
Page 142: ...1143100 SmartPAC PRO User Manual 142 Chapter 4 SmartPAC PRO Program Mode ...
Page 200: ...1143100 SmartPAC PRO User Manual 200 Chapter 6 Using DiProPAC Die Protection Optional ...
Page 222: ...1143100 SmartPAC PRO User Manual 222 Chapter 7 ProCamPAC Instructions ...
Page 254: ...1143100 SmartPAC PRO User Manual Appendix C SmartView Remote Viewing and E mail Setup 254 ...
Page 280: ...SmartPAC PRO User Manual 1143100 280 Appendix C Reporting Downtime and Scrap to SFC ...
Page 290: ...SmartPAC PRO User Manual 1143100 290 Index Y yellow fault 232 yellow sensor 169 ...
Page 292: ......
Page 294: ......
Page 296: ......
Page 298: ......
Page 300: ......
Page 301: ......
Page 302: ......
Page 303: ......
Page 304: ......
Page 305: ......
Page 306: ......
Page 307: ......
Page 308: ......
Page 309: ......
Page 310: ......
Page 311: ......
Page 312: ......
Page 313: ......
Page 314: ......
Page 315: ......
Page 316: ......
Page 317: ......
Page 318: ......