1126700
SmartPAC 2 User Manual
7-10
Fault Messages
Fault message for red sensors “This N/C sensor is open”
Explanation:
A red sensor has actuated (i.e., is open to ground). When this message is
displayed, the angle at which the condition was detected is shown.
Remedy: Check for the press or equipment malfunction that the sensor was
supposed to detect. If no malfunction has occurred, check for a problem
with the sensor. Check for loose or detached wiring at the DSI 2 or
controller. Check for a severed wire from the sensor to the DSI 2 or
controller.
Miscellaneous Fault Messages
“Maximum press speed exceeded”
Explanation:
The press is running at a speed greater than the maximum limit
programmed for this tool.
Remedy:
After clearing the error, either run the press at a slower speed, or adjust the
limit set in Program mode (see PRESS SPEED, page 5-48).
“Minimum press speed exceeded”
Explanation:
The press is running at a speed less than the minimum limit programmed
for this tool.
Remedy:
After clearing the error, either run the press at a higher speed, or adjust the
limit set in Program mode (see PRESS SPEED, page 5-48).
“The resolver position is different from when the unit was turned off”
Explanation: This message will only appear if SmartPAC 2 detects that the resolver
angle when the press is turned on is different from the angle when the
press was turned off. This can happen when you move the press or
upgrade SmartPAC 2 firmware.
Remedy:
Press RESET to clear. If the message reappears, call Wintriss Tech.
Support.
“One of the sensor auto enable counters is greater than 99”
Explanation:
Normally, this fault will never occur since SmartPAC 2 does not let you
enter a value greater than 99. However, this message could display if
there is an internal problem with SmartPAC 2.
Remedy:
First press RESET. If the message reappears, contact Wintriss Tech.
Support.
Summary of Contents for SmartPAC2
Page 21: ...1126700 SmartPAC 2 User Manual xviii Table of Contents ...
Page 143: ...1126700 SmartPAC 2 User Manual 4 46 Initialization Mode ...
Page 197: ...1126700 SmartPAC 2 User Manual 5 54 Program Mode ...
Page 233: ...1126700 SmartPAC 2 User Manual 6 36 Run Mode ...
Page 245: ...1126700 SmartPAC 2 User Manual 7 12 Fault Messages ...
Page 271: ...1126700 SmartPAC 2 User Manual B 12 Updating SmartPAC 2 Firmware ...
Page 309: ...1126700 SmartPAC 2 User Manual E 6 Replacing SmartPAC 2 PC Board ...
Page 379: ......
Page 380: ......
Page 381: ......
Page 382: ......
Page 383: ......