Initialization Mode
Settling Time Compensation for Link Motion
If SETTLING TIME is a Feed Control Initialization parameter, follow the instructions below
to compensate for speed variation. Once you have set the Settling Time to the appropriate
value for one tool, you can use the Feed Advisor for all other tools on this press.
1.
Access the Main Initialization Menu, and select FEED CONTROL.
2.
On the Feed Control screen that displays, select SETTLING TIME and set it to 30 mS.
3.
Switch to Program Mode (see Table 4-1, page 4-2), select the tool that is currently loaded,
then, on the Tool Programming Menu, select FEED CONTROL (see Changing Settings
for a Loaded Tool, page 5-6.)
4.
On the Servo-Feed Parameters screen, select FEED ADVISOR, then on the Servo-Feed
Advisor screen, select CALCULATE.
5.
Press RESET to return to the Tool Programming Menu, then press F5 (Load This Tool) to
load the tool. Cycle the press and notice whether feeding is complete at the correct time.
•
If feeding is complete at the correct time, you are finished with settling time
compensation for link motion.
•
If feeding is completed too late, access the Main Initialization Menu, select FEED
CONTROL, and increase the SETTLING TIME value by 3 mS. Then return to
Program mode, and use Feed Advisor to calculate a new value with this setting (see
steps 3 and 4). Load the tool number, and run the press to observe the feeding again.
Continue to increase the settling time by 3-mS increments until feeding is complete at
the correct time.
•
If feeding is completed too soon, access the Main Initialization Menu, select FEED
CONTROL, and decrease the SETTLING TIME value by 3 mS. Then return to
Program mode, and use Feed Advisor to calculate a new value with this setting (see
steps 3 and 4). Load the tool number, and run the press to observe the feeding again.
Continue to decrease the settling time by 3-mS increments until feeding is complete at
the correct time.
Press Speed Compensation for Link Motion
If SETTLING TIME is not a Feed Control Initialization parameter, follow the instructions
below to compensate for speed variation. You must perform this procedure for every tool the
first time you program it.
1.
Access Program mode (see Table 4-1, page 4-2), select the tool that is currently loaded,
then, on the Tool Programming Menu, select FEED CONTROL (see Changing Settings
for a Loaded Tool, page 5-6.).
Perform the press speed compensation procedure for each tool if Settling Time is not an
initialization parameter for this SFI.
NOTICE
Summary of Contents for SmartPAC2
Page 21: ...1126700 SmartPAC 2 User Manual xviii Table of Contents ...
Page 143: ...1126700 SmartPAC 2 User Manual 4 46 Initialization Mode ...
Page 197: ...1126700 SmartPAC 2 User Manual 5 54 Program Mode ...
Page 233: ...1126700 SmartPAC 2 User Manual 6 36 Run Mode ...
Page 245: ...1126700 SmartPAC 2 User Manual 7 12 Fault Messages ...
Page 271: ...1126700 SmartPAC 2 User Manual B 12 Updating SmartPAC 2 Firmware ...
Page 309: ...1126700 SmartPAC 2 User Manual E 6 Replacing SmartPAC 2 PC Board ...
Page 379: ......
Page 380: ......
Page 381: ......
Page 382: ......
Page 383: ......