SmartPAC 2 User Manual
1126700
Program Mode
5-27
2.
Decrement the CRITICAL ANGLE default value of 185
°
, using the Down (
) cursor
key, until the value you want is displayed. SmartPAC 2 accepts Critical Angle values
between 0
°
and 184
°
.
3.
Press ENTER when you are done.
If the sensor you are programming is a Green, Green Quick Check, or Green Constant
sensor, the Ready Signal Programming screen displays (see next section).
If the sensor you are programming is a red or yellow sensor, you are finished, and you are
taken to the Sensor Settings screen (see Viewing and Changing Sensor Settings,
page 5-30).
After you have programmed one or more Smart Stop sensors, you can change the critical
angle by performing these steps:
1.
On the Die Protection Sensor Menu, select a sensor programmed as Smart Stop. The
Sensor Settings screen (see Figure 5-30, page 5-30) displays.
2.
Select SMART STOP. The Sensor Stop Type screen displays with SMART STOP
highlighted.
3.
Press F5 (Set Critical Angle) to display the Critical Angle Programming screen.
4.
Change the Critical Angle setting, using the Up (
) and Down (
) cursor keys.
Setting the Ready Signal for a Green Sensor
After you select the stop type for a Green, Green Quick Check, or Green Constant sensor, the
Ready Signal Programming screen, shown in Figure 5-28, page 5-28, displays.
On this screen, you set the Ready signal for Green, Green Quick Check, and Green Constant
sensor types. The Ready signal is the timing window during which the sensor must actuate to
prevent SmartPAC 2 from sending a stop signal to the press. In the example shown in
Figure 5-28, the Ready On signal is set to 180
°
, the Ready Off signal to 265
°
.
For Green and Green Quick Check sensors, you set the Ready signal so that it is a little longer
than the sensor’s actuation time. You set the Ready signal for Green Constant sensors so that
it is a little shorter than the sensor’s actuation time. See Understanding Sensor Terminology,
page 5-16 for more information.
The Critical Angle default of 185
°
cannot be used as your Smart Stop critical angle setting.
If you attempt to enter 185
°
as the critical angle, a window will open, asking you to enter a
different value.
The critical angle can only be set for values between 0
°
and 184
°
. If you attempt to enter
185
°
as the critical angle, a window will open, asking you to enter a different value.
NOTICE
NOTICE
Summary of Contents for SmartPAC2
Page 21: ...1126700 SmartPAC 2 User Manual xviii Table of Contents ...
Page 143: ...1126700 SmartPAC 2 User Manual 4 46 Initialization Mode ...
Page 197: ...1126700 SmartPAC 2 User Manual 5 54 Program Mode ...
Page 233: ...1126700 SmartPAC 2 User Manual 6 36 Run Mode ...
Page 245: ...1126700 SmartPAC 2 User Manual 7 12 Fault Messages ...
Page 271: ...1126700 SmartPAC 2 User Manual B 12 Updating SmartPAC 2 Firmware ...
Page 309: ...1126700 SmartPAC 2 User Manual E 6 Replacing SmartPAC 2 PC Board ...
Page 379: ......
Page 380: ......
Page 381: ......
Page 382: ......
Page 383: ......