SmartPAC 2 User Manual
1126700
Installation
2-5
Connecting Wires to Terminal Block Connectors
Connect wires to terminal block connectors as follows:
1.
To connect a wire, find the correct terminal and loosen the screw over it by turning it
counterclockwise (see Figure 2-2).
2.
Strip the correct wire for this terminal 1/4 in. (6.4 mm) from end.
3.
Insert bare wire into the terminal 90% of the way. Tighten the screw. The metal tooth
inside will clamp down on the bare wire for a tight connection. Make sure that the metal
tooth is clamped down on the bare part of the wire, not on the insulation.
4.
Connect all wires. Double-check connections when done.
5.
Plug the connector firmly into the receptacle on the PC board. The connector can fit into
the receptacle in only one direction.
Terminating Cable Shields
Your SmartPAC 2 has ground studs on the inside of the enclosure for terminating cable
shields at their point of entry.
CONNECTOR WIRING
The connector can plug into the receptacle on the PC board in only one direction. Before wiring
the connector, mark its left and right ends when it is plugged in to make sure you wire the correct
pin numbers.
Figure 2-2. Attaching Wires to Connector
TERMINATE BOTH ENDS OF SHIELD
Be sure to terminate cable shields at both ends (for example, at SmartPAC 2 and DSI 2).
NOTICE
Insert wire here
Tighten screw to clamp
wire in terminal
NOTICE
Summary of Contents for SmartPAC2
Page 21: ...1126700 SmartPAC 2 User Manual xviii Table of Contents ...
Page 143: ...1126700 SmartPAC 2 User Manual 4 46 Initialization Mode ...
Page 197: ...1126700 SmartPAC 2 User Manual 5 54 Program Mode ...
Page 233: ...1126700 SmartPAC 2 User Manual 6 36 Run Mode ...
Page 245: ...1126700 SmartPAC 2 User Manual 7 12 Fault Messages ...
Page 271: ...1126700 SmartPAC 2 User Manual B 12 Updating SmartPAC 2 Firmware ...
Page 309: ...1126700 SmartPAC 2 User Manual E 6 Replacing SmartPAC 2 PC Board ...
Page 379: ......
Page 380: ......
Page 381: ......
Page 382: ......
Page 383: ......