www.ghibliwirbel.com
Professional Cleaning Machines Since 1968
ENGLISH
- 13
TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
The machine does not start
when pressing the central
button.
Low battery (for BC version
only).
Check that the battery is
charged.
Plug disconnected (for E ver-
sion only).
Connect the plug.
Main fuse blown (for BC ver-
sion only).
Replace the GREEN 30A
main fuse.
The brush does not rotate.
Brush unit outlet overcurrent
error or brush unit open cir-
cuit error.
See paragraph “Warning
signals while using the ma-
chine”.
Brush motor damaged.
Replace the ratiomotor.
Brush rotation enabling but-
ton not pressed.
Press the button.
Aspirator does not work.
Suction unit outlet overcur-
rent error or suction unit open
circuit error
.
See paragraph “Warning
signals while using the ma-
chine”.
Intake motor damaged.
Replace the turbine.
Aspirator enabling button not
pressed.
Press the button.
The machine does not dry
well, leaving traces of water
on the floor.
Aspirator off.
Start up the aspirator.
Aspiration tube blocked.
Check and if necessary clean
the aspiration tube that con-
nects the squeegee to the re-
covery tank.
Squeegee rubbers not cor-
rectly set up.
Set up the squeegee rubbers
as indicated in paragraph
“Squeegee setting”
.
Recovery tank full.
Empty the recovery tank.
Squeegee rubber blades
worn.
Replace or turn over the
squeegee rubber blades.
Man_RAPID15_E38_M38BC-M38HYBRID_3ed_06-2020_49025101.indd 13
Man_RAPID15_E38_M38BC-M38HYBRID_3ed_06-2020_49025101.indd 13
11/06/2020 15:51:34
11/06/2020 15:51:34