www.ghibliwirbel.com
Professional Cleaning Machines Since 1968
ENGLISH
- 14
PROBLEM
CAUSE
SOLUTION
No water comes out.
Tank empty.
Fill the tank.
Solenoid valve enabling but-
ton not pressed.
Press the button.
Tap turned off.
Turn on the tap located at the
bottom of the machine.
Filter blocked.
Clean the filter.
Solenoid valve does not work. Call the technical support ser-
vice.
Insufficient floor cleaning.
Unsuitable brushes or deter-
gent.
Use brushes or detergents
which are suitable for the type
of floor or dirt to be cleaned.
Brush worn.
Replace the brush.
BC - BC Lithium versions
A1
....................................Printed circuit board
BAT
............................2 x 12 V battery (BC)
BAT
...............
1 x 24 V battery (BC Lithium)
U1
...................................5A battery charger
Y1
.............................................Electrovalve
F1
......................................... Main fuse 30A
M1
.........................................Vacuum motor
M2
.............................................Brush motor
P1
..............................………. ON/OFF switch
P2
..................................……… Brush button
P3
..................................Vacuum interruptor
P4
........................... Electrovalve interruptor
R1
..............................Battery level indicator
CN1
................………....... Handle connector
CN2
..........…....... Battery charger connector
Man_RAPID15_E38_M38BC-M38HYBRID_3ed_06-2020_49025101.indd 14
Man_RAPID15_E38_M38BC-M38HYBRID_3ed_06-2020_49025101.indd 14
11/06/2020 15:51:35
11/06/2020 15:51:35