WireCrafters
Adjustable Panel Installation
Adjustable Panel (AP) Installation
Used to fill gaps of 1” to 11” in partition runs.
1.
Place 3-1/4” spacer block under non-supported end of partition run.
2.
Fit the AP panel in the gap between the end post (or building wall)
and wire mesh panel.
a.
The flat edge of the AP panel should overlap the face side of
the wire mesh panel, and the edge with the 90 degree bend
should be against the post or wall.
3.
Bolt the angle edge of the AP to the post using two 3/8” x 3”straight
bolts, or two 3/8” corner bolts (use wall mount kit if mounting to
building wall).
4.
Attach flat side of one AP to face side of bottom panel on partition
wall by placing two 3/8” x 1” carriage bolts through the AP, mesh
and adjustable flats (part APFL); secure with 3/8” nuts per Fig.1.
5.
Bolt the angle edge of the AP to the post using two 3/8” x 3”straight
bolts, or two 3/8” corner bolts (use wall mount kit if mounting to
building wall).
6.
Repeat for upper panel.
7.