Quick Start Guide (G4)
Author: Ben Darrington
2
A
DDING
R
ECEIVERS TO A
U
NIVERSE
T
O CONNECT RECEIVERS FROM THE
T
RANSMITTER
(F-1
AND
F-2
IN
T
RANSMIT
M
ODE
)
Note: You can add receivers at any time, even during operation.
1.
Power on the receiver unit(s) and ensure that they are not linked with any other transmitter (LINK
indicators should be OFF). If the units are linked, follow the instructions in the next section to unlink
receivers.
2.
On the transmitter unit, press and release the FUNCTION button quickly. The transmitter will scan for all
unlinked receivers for a period of ten seconds - the LINK indicator will flash rapidly.
If successful, each receiver’s LINK indicator will go ON. If any failed (i.e. the link indicator fails to go solid after 10
seconds on the receiver), check that the receiver is in range and repeat procedure.
D
ISCONNECTING
R
ECEIVERS FROM A
U
NIVERSE
T
O UNLINK ALL RECEIVERS FROM THE TRANSMITTER
(F-1
AND
F-2
IN
T
RANSMIT
M
ODE
)
1.
On the transmitter unit, press and hold the FUNCTION button for 3 seconds. All display LEDs will go out,
except for POWER and TX, and the LINK LED will be blinking slowly. Release the function button at this
point, and all connected receivers will be unlinked.
T
O UNLINK AN INDIVIDUAL RECEIVER
(F-1
AND
F-2
I
N
R
ECEIVE
M
ODE
,
R-512)
1.
On the receiver, press and hold the FUNCTION button until the LINK indicator goes OFF. The receiver is
now unlinked.