background image

14A

60N2F32

14B

40N2F31

60N2C08

60N2B08

3"

[76mm]

40N2C08

40N2B08

5 1/2"

[140mm]

60N2F55*

40N2F55**

40N2C08

* 60N2F55 is used when installing data/communications devices in the power channel 

in order to maintain maximum capacity for data/communications cabling.

** 40N2F55 is required to mount devices into 40N2B08 Raceway.

1

2

3

4

1

2

3

1

2

3

15

40N2F74, 60N2F74

1

Summary of Contents for 40N2 Series

Page 1: ...ctrical Code Canadian Electrical Code or codes administered by local authorities All electrical products may represent possible shock or fire hazard if improperly installed or used Wiremold electrical products are UL listed made for interior use only and should be installed in conformance with current local and or the National Electrical Code Recommended Cutting Tools Fasteners Herramientas de cor...

Page 2: ...6 457mm 30 762mm 1 2B 3 4 6 7 5A 5B 40N2B08 60N2B08 2A 40N2C08 60N2C08 40N2FWC 60N2FWC 40N2F05 60N2F05 40N2F06 60N2F06 40N2F11 60N2F11 40N2F15 60N2F15 40N2B08 60N2B08 60N2B08 40N2B08 60N2B08 30 762mm A B ...

Page 3: ...4 1 1 1 4 and 1 1 2 Conduit for 40N2F21 40N2F17 60N2F17 60N2F18 10 40N2F19 60N2F19 11 40N2F20 60N2F20 12 40N2F21 60N2F21 MXN2A08 1 2 3 4 conduit 13 60N2F8R 60N2F8L Wire Size NO OF THHN THWN CONDUCTORS 14 AWG 20 12 AWG 18 10 AWG 17 8 AWG 15 6 AWG 5 ...

Page 4: ...m 60N2F55 40N2F55 40N2C08 60N2F55 is used when installing data communications devices in the power channel in order to maintain maximum capacity for data communications cabling 40N2F55 is required to mount devices into 40N2B08 Raceway 1 2 3 4 1 2 3 1 2 3 15 40N2F74 60N2F74 1 ...

Page 5: ...14 28 7 14 RG6 U 0 270 6 9 11 22 5 11 TWINAXIAL 100 Ohm 0 330 8 4 7 15 4 8 SHIELDED TYPE 1 0 390 9 9 5 10 2 5 TWISTED PAIR TYPE 2 0 465 11 8 3 7 2 4 TYPE 3 0 245 6 2 13 27 7 14 FIBER Mini Zip Cord 0 079 x 0 157 2 x 4 51 103 27 55 Zip Cord 0 118 x 0 236 3 x 6 23 46 12 24 Round 4 Strand Fiber 0 187 4 8 23 46 12 24 Round 6 Strand Fiber 0 256 6 5 12 25 6 13 40N2 RACEWAY WIRE FILL CAPACITIES FOR DATA C...

Page 6: ...when using both channels for power 3 20 cable fill calculated to approximate reduction in cable capacity due to connectors mounted within raceway and fittings that may restrict cross sectional area 4 40 cable fill is the maximum designed cable fill based on TIA EIA 569 A O D Approx Dia CABLE WIRE SIZE Inches mm 20 FILL 40 FILL UNSHIELDED 4 pair 24 AWG Cat 3 0 190 4 8 30 60 TWISTED PAIR 4 pair 24 A...

Page 7: ...d Distributor Click to View Pricing Inventory Delivery Lifecycle Information Wiremold 40N2B08WH 40N2C08WH 40N2F05WH 40N2F06WH 40N2F11WH 40N2F15WH 40N2F17WH 40N2F19WH 40N2F20WH 40N2F31WH 40N2F55 40N2FWC 40N2F21WH 40N2B08V 40N2C08V ...