repeated matings. 
   

A: 

If the bulkhead adapter sleeve is made from phosphor-bronze, some of 

the metal is probably rubbing off on the connectors. 
 

3.0

 

INSTALLATION 

3.1

 

Unpacking 

Inspect the shipping boxes for any obvious damages.   
Unpack the unit from all packaging boxes. 
Inspect the appearance of the unit for any shipping damages.   
Document and inform the shipping company and your local representative, 
as seen in section 1.2, of the damages. 
Save  the  shipping  boxes  and  their  inserts  for  any  future  reshipment  for 
upgrade or repair. 

NOTE: In the event of a reshipment back to the manufacturer, any additional 
damages  caused  by  not  using  the  original  boxes  will  be  considered 
responsibility of the customer. 

3.2

 

EDFA Mounting and Power Connection 

1.

 

Place the unit into a 19-inch wide rack or cabinet. Make sure to leave a 

1.75-inch (about 4.5cm) space above and below the unit. 

2.

 

According to the design request, HA5800A series 1550nm EDFA can work 

under  0°C~50°C  (32°F~122°F)  temperature  range.  We  recommend  25°C 
(77°F) environment temperature. 

Humidity  not  bigger  than  95%(under  non-coagulation  condition).  If 
necessary, the equipment should keep the suitable temperature & humidity 
in  the  restrained  scope.  We  recommend  to  operating  in  the  environment 
without dust. 

3.

 

Equipment powered by AC or steady voltage DC. In both of AC & DC, AC 

is the chief power supply. 

Request of power supply: 

AC input   

94-245VAC, 50-60Hz 

DC input   

36-60VDC, floating 

Power consumption 

Maximum 50W 

4.

 

The  DC  power  supply  of  the  equipment  must  be  the  SELV  supply 

stipulated as CAN/CSA C22.2 No.950-95 standard. 

5.

 

The  machine  should  have  good  grounding,  grounding  resistance<4Ω. 

According to the international standard, 220V plug in adopts tri-wire rule, 

Summary of Contents for HA5800A Series

Page 1: ...1 15 55 50 0n nm m C CA AT TV V E Er rb bi iu um m D Do op pe ed d F Fi ib be er r A Am mp pl li if fi ie er r H HA A5 58 80 00 0A A S Se er ri ie es s U US SE ER R M MA AN NU UA AL L Ver 2 2en ...

Page 2: ...TION 4 3 1 Unpacking 4 3 2 EDFA Mounting and Power Connection 4 3 3 Optic connection 5 4 0 EDFA CONTROLS INDICATORS AND ALARMS 6 4 1 The operation of the pane 6 5 0 PORT AND CABLE ASSIGNMENTS 9 5 1 Management Port RJ 45 9 5 2 RS232 Console port DB9 12 5 3 Power Connection 13 6 0 FAULT DISPOSAL 13 6 1 Warning status 13 6 2 Alarm status 14 6 3 Fault prevention 14 7 0 GUARANTEE AND REPAIR ITEMS 15 ...

Page 3: ...ke other kind of product which need high optical power input to maintain lower noise figure HA5800A optical amplifier adopts the world s top class pump laser and active optical fiber Perfect APC ACC and ATC control excellent design in the ventilation and heat dissipation ensure the long life and high reliable work of pump laser RS232 and RJ45 offer serial commutation and SNMP network management po...

Page 4: ... will cause low output power If user need to plug in out or adjust the output connector firstly please turn off the unit with key KEY OFF 2 2 Connector cleaning guide Optical fiber connectors require care and careful cleaning Caps should be left on connectors whenever they are not in use Do not touch the connector end Damage to connector end faces caused by improper care is not covered by the warr...

Page 5: ...ese connectors should be kept to a minimum Bulkhead cleaning Fiber bulkhead adapters contain a zirconia or phosphor bronze sleeve After removing the connectors these can be cleaned with a pipe cleaner moistened with isopropyl alcohol and dried with canned air Trouble shooting Q A small black area appears in the middle of the connector which cannot be remove by cleaning A Some material typically oi...

Page 6: ...lace the unit into a 19 inch wide rack or cabinet Make sure to leave a 1 75 inch about 4 5cm space above and below the unit 2 According to the design request HA5800A series 1550nm EDFA can work under 0 C 50 C 32 F 122 F temperature range We recommend 25 C 77 F environment temperature Humidity not bigger than 95 under non coagulation condition If necessary the equipment should keep the suitable tem...

Page 7: ...with at least the following specifications Non residue inert gas for precision dust removal Ultra filtered to 0 2 microns Recommended for optical systems Using compressed air as listed above remove the bulkhead dust cover and hold the can of compressed air about 6 inches from the connector After spraying a few short bursts into the bulkhead the connector is clean and ready for connection If compre...

Page 8: ...key switch to the OFF position 4 0 EDFA CONTROLS INDICATORS AND ALARMS This section of the manual will give an overview of the available menus in the HA5800A series EDFA and their descriptions All instructions in Section 4 0 refer to the representation of the front panel shown in the diagram below The user scrolls through the menus by pushing the bottoms found on the front panel of the EDFA just i...

Page 9: ...le list display the optical route Status Menu 8 Op Switch Point Adjustable list display the optical switch point setting Menu 9 Set Output Adjustable list displays the output power Menu 10 Total Output Read only menu tells the output optical power of EDFA in dBm Menu 11 Each Output Read only menu tells the each output of EDFA in dBm Menu 12 PA Current Read only menu tells the pre pump current of E...

Page 10: ...se the working mode of optical switch last press the button at the same time to save 2 OP Route Status set optic fiber route Select the menu mode need to modify and press the button at the same time to enter modified status press the button to select mode of optic fiber route last press the button at the same time to save 3 Op Switch Point set switch point of optical switch Select the menu mode ne...

Page 11: ...r modify status press button to increase or decrease the value press at same time to save 7 Set Reset Settings menu Choose Reset Setting menu press button at same time to enter modify status press button to select the restore factory setting press the button at the same time to save and exit 5 0 PORT AND CABLE ASSIGNMENTS HA5800A series provide the following manage port RS232 port be suitable for ...

Page 12: ...nment When network management reticle RJ 45 connector in each side connects NMS PC and HA5800A series directly it should use straight reticle See Figure 5 1 2 Figure 5 1 2 RJ 45 connector straight through connecting PIN Workstation port MDI 1 Input receive data Output transmit data 2 Input receive data Output transmit data 3 Output transmit data Input receive data 6 Output transmit data Input rece...

Page 13: ...nly twisted pair cables with RJ 45 connectors that conform to FCC standards Note 1 Connect other compatible HA5800A series or network hub adopt direct or across cable to connect MDI port in other device 2 Ensure that the twisted pair cable length does not exceed 100 meters 3 Cat 5 cable is recommended for all network connections to avoid confusion or inconvenience when upgrading to Fast Ethernet d...

Page 14: ...ector which is the same as the connector of PC Com interface 5 2 2 Pin assignment Figure 5 2 2 DB9 RS232 pin assignment Pin Distribution 2 RXD accepting of data 3 TXD transmitter data 5 SG signal Table 5 3 Pin information 5 2 3 Port connection HA5800A series is equipped with a cable to connect HA5800A series serial port This cable has a DB9 connector in HA5800A series and PC side Consult figure 5 ...

Page 15: ... as system parameter floating equipment tolerance laser aging RF level changing and temperature changing The PUMP laser will go on working when alarming The alarm will disappear through the facility is self detected continually or relative system parameter recovers into normal range Some serious warning can be eliminated by restart the power supply of the equipment The warning will disappear autom...

Page 16: ...rameter exceeding its safety working scope or some situation causes damage to the laser Some alarm could be eliminated by restart the power supply or reset the key switch For user couldn t eliminate some alarm please contact our company immediately 6 3 Fault prevention User can notice below information to prevent some potential problems 1 Please place the pump laser under environment temperature 0...

Page 17: ...tc pump laser will not be damaged only by man induced factor In case of Red lamp sparking Alarm Please return for repairing User should not open the top cover for repair otherwise even within guarantee period maintain and material fee will be charged 3 Lifelong maintain and upgrade is provided even guarantee period is expired 4 If component is damaged by man induced factor material fee will be cha...

Reviews: